Effect of Different Computer-aided Design/Computer-aided Manufacturing (CAD/CAM) Materials and Thicknesses on the Fracture Resistance of Occlusal Veneers

Author:

Andrade JP1,Stona D2,Bittencourt HR3,Borges GA4,Burnett LH,Spohr AM5

Affiliation:

1. Jonas Pereira Andrade, DDS, MS, Pontifical Catholic University of Rio Grande do Sul, Restorative Dentistry, Rio Grande do Sul, Brazil

2. Deborah Stona, DDS, MS, Pontifical Catholic University of Rio Grande do Sul (PUCRS), School of Dentistry, Department of Restorative Dentistry, Rio Grande do Sul, Brazil

3. Hélio Radke Bittencourt, MS, PhD, Pontifical Catholic University of Rio Grande do Sul, Statistics, Rio Grande do Sul, Brazil

4. Gilberto Antonio Borges, DDS, MS, PhD, Uberaba University, Restorative Dentistry, Minas Gerais, Brazil

5. Ana Maria Spohr, DDS, MS, PhD, Pontifical Catholic University of Rio Grande do Sul, Dental Materials, Rio Grande do Sul, Brazil

Abstract

SUMMARY The aim was to evaluate, in vitro, the influence of different computer-aided design/computer-aided manufacturing (CAD/CAM) materials (IPS e.max CAD, Vita Enamic, and Lava Ultimate) and thicknesses (0.6 mm and 1.5 mm) on the fracture resistance of occlusal veneers. Sixty human third molars were prepared to simulate advanced erosion of the occlusal surface, and the teeth were randomly divided into six experimental groups (n=10) according to the material and thickness used to build the veneers. Ten sound teeth formed the control group. The veneers were adhesively luted and submitted to mechanical cyclic loading (1 million cycles at 200-N load). The fracture resistance test was performed in a universal testing machine. The failures were classified as “reparable” and “irreparable.” According to two-way analysis of variance and the Tukey test, the interaction (material × thickness) was significant (p=0.013). The highest fracture resistance was obtained for IPS e.max CAD at a 1.5-mm thickness (4995 N) and was significantly higher compared to the other experimental groups (p<0.05). The lowest fracture resistance was obtained for Vita Enamic at 0.6 mm (2973 N), although this resistance was not significantly different from those for IPS e.max CAD at 0.6 mm (3067 N), Lava Ultimate at 0.6 mm (3384 N), Vita Enamic at 1.5 mm (3540 N), and Lava Ultimate at 1.5 mm (3584 N) (p>0.05). The experimental groups did not differ significantly from the sound teeth (3991 N) (p>0.05). The failures were predominantly repairable. The occlusal veneers of IPS e.max CAD, Vita Enamic, and Lava Ultimate, with thicknesses of 0.6 mm and 1.5 mm, obtained fracture resistances similar to those associated with sound teeth.

Publisher

Operative Dentistry