Effect of Different Adhesive Systems Used for Immediate Dentin Sealing on Bond Strength of a Self-Adhesive Resin Cement to Dentin

Author:

Ferreira-Filho RC1,Ely C2,Amaral RC3,Rodrigues JA4,Roulet J-F5,Cassoni A6,Reis AF7

Affiliation:

1. Ramiro Chavasco Ferreira-Filho, MS, Department of Operative Dentistry, Guarulhos University, Guarulhos, Brazil

2. Caroline Ely, DDS, MS, PhD, Department of Operative Dentistry, Guarulhos University, Guarulhos, Brazil

3. Roberto C Amaral, DDS, MS, Dental Materials and Restorative Dentistry, University of Oeste of Santa Catarina, Joacaba, Brazil

4. José Augusto Rodrigues, DDS, MS, PhD, Department of Restorative Dentistry, Guarulhos University, Guarulhos, Brazil

5. Jean-Francois Roulet, DDS, PhD, College of Dentistry, University of Florida, Gainesville, FL, USA

6. Alessandra Cassoni, PhD, Department of Restorative Dentistry, Guarulhos University, Guarulhos, Brazil

7. Andre F Reis, DDS, MS, PhD, Department of Operative Dentistry, Guarulhos University, Guarulhos, Brazil

Abstract

SUMMARY Objective: The purpose of this study was to investigate the immediate and three-month water storage behavior of adhesives when used for immediate dentin sealing (IDS). Methods and Materials: Four adhesive systems were used to perform IDS: a one-step self-etch (Xeno V), a two-step self-etch (Clearfil SE Bond), a two-step etch-and-rinse (XP Bond), and a three-step etch-and-rinse (Optibond FL). For the control group, IDS was not performed. The self-adhesive resin cement RelyX Unicem was used for the luting procedures. After seven days of water storage, specimens (n=6) were sectioned into beams (n=5) with an approximately 1-mm2 cross-sectional area. Half of the specimens were tested in tension after seven days of water storage at 37°C, while the other half was stored for three months prior to testing in tension using a universal testing machine (1 mm/min). The failure pattern was determined using a stereomicroscope and scanning electron microscopy. Microtensile bond strength (μTBS) data were statistically analyzed by two-way analysis of variance and Tukey post hoc test (α=0.05). Results: After seven days, the control group presented the lowest μTBS but did not differ from XP Bond and Clearfil SE Bond. After three months, there was no μTBS difference between the IDS groups and the control. Conclusions: After seven days of water storage, the groups with IDS presented higher μTBS values than the control group, although XP Bond and Clearfil SE Bond did not present significant differences. However, after three months of storage in water, IDS groups did not differ significantly from control group, which did not receive IDS.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3