Effects of Adjacent Tooth Type and Occlusal Fatigue on Proximal Contact Force of Posterior Bulk Fill and Incremental Resin Composite Restoration

Author:

Oliveira LRS1,Melo C2,Cavalcanti KGBA3,Soares PBF4,Cardenas AFM5,Soares CJ6

Affiliation:

1. Lais Rani Sales Oliveira, DDS, MSc, PhD student, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlandia, MG, Brazil

2. Calebe de Melo, DDS, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil

3. Karoline Guará Brusaca Almeida Cavalcanti, DDS, MSc, PhD student, School of Dentistry, CEUMA University, São Luis, MA, Brazil

4. Priscilla Barbosa Ferreira Soares, DDS, MSc, PhD, professor, Department of Periodontology and Implantology, School of Dentistry, Universidade de Uberlândia, Uberlândia, MG, Brazil

5. Andres Felipe Millan Cardenas, DDS, MSc, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil

6. *Carlos José Soares, DDS, MSc, PhD, professor, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlandia, Minas Gerais, Brazil

Abstract

SUMMARY Objectives To measure the proximal contact force in newtons (N) between incremental and bulk fill class II resin composite restorations and implant molar teeth or adjacent premolar teeth with simulated periodontal ligament. Methods The model used was created with a typodont first molar tooth with two bilateral occlusal-proximal class II cavities, an adjacent tooth simulating an implanted molar tooth (Titamax CM, Neodent, Curtiba, PR, Brazil) and a premolar with simulated periodontal ligament. Two resin composite restorative techniques were used: Inc-Z350XT, (Filtek Z350, 3M Oral Care, St. Paul, MN, USA) inserted incrementally and Bulk-OPUS, (Opus Bulk Fill APS, FGM, Joinville, SC, Brazil) high viscosity bulk fill resin composite (n=10). As a control, a typodont having intact teeth without restorations was used. After the restorative procedure, each specimen was radiographed using a digital system (Dürr Dental, Bietigheim-Bissingen, Germany). The proximal contact force (N) was measured using dental floss with a microtensile machine (Microtensile ODEME, Luzerna, SC, Brazil). The specimens were then subjected to mechanical fatigue cycling to simulate 5 years of aging. All the parameters were measured after aging. The X-rays were blindly qualitatively analyzed by two operators to identify the loss of proximal contact. One-way ANOVA was used for comparing the initial contact force between restored and intact teeth. Two-way ANOVA followed by Tukey testing was performed for contact area data and for the contact force/contact area ratio. The proximal contact force data were analyzed using one-way repeated measurement ANOVA followed by Tukey testing (α=0.05). The X-ray proximal contact analyses were described by the frequency. Results The initial proximal contact force was similar for intact and restored teeth. The contact force and contact area with the molar were significantly higher than with the premolar; however the contact force/contact area ratio was similar for all tested groups. The bulk fill technique showed a contact force similar to the incremental filling technique. Fatigue resulted in a significant reduction in the proximal contact force (p<0.001), irrespective of the region analyzed or restorative material used. The digital X-rays detected no alteration in the proximal contact after occlusal fatigue. Conclusions Larger contact area resulted in higher proximal contact force. Proximal contact force decreased with 5 years of simulated occlusal fatigue. The bulk fill technique showed a proximal contact force similar to that of the incremental filling technique.

Publisher

Operative Dentistry

Subject

General Dentistry

Reference47 articles.

1. Clinical effectiveness of direct class II restorations—A meta-analysis;Heintze;Journal of Adhesive Dentistry,2012

2. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition;Manhart;Operative Dentistry,2004

3. Clinical evaluation of posterior composite restorations: The 10-year report;Gaengler;Journal of Adhesive Dentistry,2001

4. 22-Year clinical evaluation of the performance of two posterior composites with different filler characteristics;Rodolpho;Dental Materials,2011

5. Evaluation of proximal contact strength by postural changes;Kim;Journal of Advanced Prosthodontics,2009

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3