Effect of Simulated Tooth Temperature on the Degree of Conversion of Self-adhesive Resin Cements Exposed to Different Curing Conditions

Author:

Arrais CAG1,Chagas CL2,Munhoz A3,Oliveira M4,Reis AF5,Rodrigues JA6

Affiliation:

1. Cesar AG Arrais, DDS, MS, PhD, Ponta Grossa State University, Department of Operative Dentistry, Ponta Grossa, Brazil

2. Carolina Levatti Chagas, DDS, MS, University of Guarulhos, Department of Operative Dentistry, Guarulhos, Brazil

3. Aurea Munhoz, BMSc, University of Guarulhos, Department of Operative Dentistry, Guarulhos, Brazil

4. Michele Oliveira, MS, DDS, University of Guarulhos, Department of Operative Dentistry, Guarulhos, Brazil

5. Andre F Reis, DDS, MS, PhD, University of Guarulhos, Department of Operative Dentistry, Guarulhos, Brazil

6. José Augusto Rodrigues, DDS, MS, PhD, University of Guarulhos, Department of Restorative Dentistry, Guarulhos, Brazil

Abstract

SUMMARY Objectives This study evaluated the degree of conversion (DC) of two commercial, self-adhesive resin cements (SARCs) using Fourier transform infrared analysis (FTIR) polymerized at simulated prepared tooth surface temperatures and under different curing conditions. Materials and Methods RelyX U100 (U100, 3M ESPE) and Maxcem Elite (MX, Kerr Corporation) were mixed at 25°C and applied to the surface of a horizontal attenuated total reflectance (ATR) unit, which was near room temperature (RT, control) (25°C) or heated to simulate prepared tooth surface temperatures (28°C and 32°C) and then attached to an infrared spectrometer. The products were polymerized using one of three conditions: direct light exposure through a glass slide (DLE), exposure through a 1.5-mm thick ceramic disc overlay (CO) (A2 shade, IPS e.max, Ivoclar Vivadent), or self-curing (SC). FTIR spectra were recorded for 12 minutes (1 spectrum/s, 16 scans/spectrum, resolution 4 cm−1) immediately after application to the ATR. The DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios before and 12 minutes after curing, as well as during each 1-second interval. DC data (n=7) were analyzed by two-way analysis of variance and Tukey's post-hoc test (p=0.05). Results Both simulated tooth temperatures significantly increased DC in all groups of MX and in the CO and SC groups of U100 compared with the RT control. For MX, the self-cure groups exposed to tooth temperatures showed DC values similar to those of the CO groups. For U100, the CO groups showed higher DC values than SC groups regardless of temperature. Time-based conversion profiles ranged according to product, temperature, and curing mode. Conclusions Causing SARCs to polymerize at simulated tooth temperatures increases DC of SARCs compared with room-temperature curing values, mainly in the SC mode.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3