Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites

Author:

Odum NC1,Ross JT2,Citrin NS3,Tantbirojn D4,Versluis A5

Affiliation:

1. Nicholas C Odum, BS, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

2. Jason T Ross, BS, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

3. Nechama S Citrin, DMD, MS, Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

4. Daranee Tantbirojn, DDS, MS, PhD, Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

5. *Antheunis Versluis, PhD, Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

Abstract

SUMMARY Objectives High-power LED curing lights and bulk-fill resin composites are intended to reduce chair time. This study investigated depth of cure, post-gel shrinkage (responsible for shrinkage stress), and heat generation in bulk-fill composites when cured according to minimum curing times recommended by manufacturers of curing lights and composites. Methods A regular LED curing light (Demi Ultra, 1350 mW/cm2, Kerr Dental) and two LED curing lights with high-power modes (VALO Grand, 3117 mW/cm2 Xtra Power, Ultradent; and Bluephase PowerCure, 2435 mW/cm2 Turbo and 3344 mW/cm2 3sCure, Ivoclar Vivadent) were tested on three bulk-fill composites (Filtek One Bulk Fill, 3M Oral Care Solutions; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; Tetric Powerfill, Ivoclar Vivadent). Using minimum times recommended by manufacturers (3, 5, 6, 10, or 20 seconds), depth of cure was determined by Vickers hardness of specimens cured in a slot (n=10). Post-gel polymerization shrinkage was measured using a strain gauge (n=10) and temperature with a thermocouple (n=5). Results were analyzed using two- and one-way analysis of variance (ANOVA) followed by pairwise comparisons or Student-Newman-Keuls post hoc tests (α=0.05). Results Curing lights and curing protocols significantly affected depth of cure, post-gel shrinkage, and temperature rise (p<0.001). Cure decreased with depth whereby best overall curing performance was achieved by the 20 second exposure at lowest irradiance (Demi Ultra). Fast curing (3–5 seconds) at high irradiance resulted in lesser depth-of-cure performance, except for the BluePhase-Tetric PowerFill combination. Post-gel shrinkage was higher in all composites when cured at high irradiance (p<0.001), while heat generated also tended to be higher. Conclusions Although the high-power LED curing lights advertise time savings, not all manufacturer recommended minimum curing times cured bulk-fill materials to the same extent. Moreover, these time savings came at a cost of higher post-gel shrinkage and generated more heat in the bulk-fill composites than the lower irradiance curing protocol.

Publisher

Operative Dentistry

Subject

General Dentistry

Reference26 articles.

1. Light curing in dentistry and clinical implications: A literature review;Rueggeberg;Brazilian Oral Research,2017

2. Shortest exposure time possible with LED curing lights;Busemann;American Journal of Dentistry,2011

3. Depth of cure of bulk fill resin composites: A systematic review;Lima;Journal of Esthetic and Restorative Dentistry,2018

4. Ivoclar Vivadent ( 2019) 3s PowerCure Scientific Documentation. Retrieved online September 2, 2021 from: https://issuu.com/ivoclarvivadent/docs/scientific_documentation_3scure_pow

5. Influence of light energy density, composite type, composite thickness, and postcuring phase on degree of conversion of bulk-fill composites;Jain;Contemporary Clinical Dentistry,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3