Two-year Randomized, Controlled Clinical Trial of a Flowable and Conventional Composite in Class I Restorations

Author:

Lawson NC1,Radhakrishnan R2,Givan DA3,Ramp LC4,Burgess JO5

Affiliation:

1. Nathaniel C Lawson, DMD, PhD, assistant professor, Clinical and Community Sciences, University of Alabama at Birmingham, Birmingham, AL, USA

2. Rashmi Radhakrishnan, BDS, MS, graduate resident, Clinical and Community Sciences, University of Alabama at Birmingham, Birmingham, AL, USA

3. Daniel A Givan, DMD, PhD, associate professor and division chair, Restorative Sciences, University of Alabama at Birmingham, Birmingham, AL, USA

4. Lance C Ramp, DMD, PhD, associate professor, Restorative Sciences, University of Alabama at Birmingham, Birmingham, AL, USA

5. John O Burgess, DDS, MS, professor and associate dean, Clinical and community Sciences, University of Alabama at Birmingham, Birmingham, AL, USA

Abstract

SUMMARY Objectives This study evaluated the two-year clinical performance and volumetric wear of a flowable resin composite compared to a conventional highly filled composite resin in Class I restorations. Methods and Materials In this single-center, single-blinded, comparator-controlled clinical study (Institutional Review Board approved), 120 carious teeth distributed in 60 patients were randomly assigned to four calibrated practitioners who placed occlusal restorations (n=60 flowable and n=60 conventional composite). Direct and indirect assessment at baseline, six months, one year, and two years occurred during which the modified Cvar and Ryge criteria were evaluated. Volumetric wear was determined by superimposition of profilometer scans of baseline and two-year casts. Results At two years, there was no significant difference in anatomic form (p=0.80), color match (p=0.08), marginal adaptation (p=0.89), marginal discoloration (p=0.79), surface integrity (p=0.18), secondary caries (p=0.66), cold sensitivity (p=0.522), occlusal sensitivity (p=0.818), or volumetric wear (p=0.661) between materials. Both materials showed a decrease in all criteria except secondary caries (p=0.95) over time. Two-year mean volumetric wear was 3.16 ± 2.38 mm3 for the flowable composite and 3.43 ± 2.50 mm3 for the conventional composite. Conclusions The flowable and conventional composites used in this study have similar clinical efficacy after two years of service when placed as Class I occlusal restorations having isthmus widths less than one-half the intercuspal distance.

Publisher

Operative Dentistry

Subject

General Dentistry

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3