Effect of the Sample Preparation and Light-curing Unit on the Microhardness and Degree of Conversion of Bulk-fill Resin-based Composite Restorations

Author:

Braga SSL1,Schettini ACT2,Carvalho ELO3,Shimokawa CAK4,Price RB5,Soares CJ6

Affiliation:

1. Stella Sueli Lourenço Braga, DDS, MSc, PhD, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil

2. Ana Cecília Teodoro Schettini, DDS, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil

3. Everton Luiz Oliveira Carvalho, DDS, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil

4. Carlos Alberto Kenji Shimokawa, DDS, MSc, PhD, professor, Department of Restorative Dentistry, Dental School, University of São Paulo, São Paulo, São Paulo, Brazil

5. Richard Bengt Price, DDS, MSc, PhD, professor, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada

6. *Carlos José Soares, DDS, MSc, PhD, Professor and Chair at Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil

Abstract

SUMMARY Objective To evaluate the effect of the sample preparation and light-curing units (LCUs) on the Knoop hardness (KH, N/mm2) and degree of conversion (DC, %) of bulk-fill resin-based composite restorations. Methods Two molds were made using human molar teeth embedded in acrylic resin. One was a conventional tooth mold where the molar received a mesio-occluso-distal (MOD) preparation. In the other, the tooth was sectioned in three slices (buccal, middle, and lingual). The center slice received a MOD preparation similar to the conventional mold. Both tooth molds were placed in the second mandibular molar position in a Dentoform with a 44-mm interincisal opening. Restorations were made using Opus Bulk Fill (FGM) high viscosity bulk-fill resin-based composite (RBC) and light cured using two different lights: VALO Cordless (Ultradent) and Bluephase G2 (Ivoclar Vivadent). The RBC was placed in one increment that was light-cured for a total of 80 seconds (40 seconds at the occluso-mesial and occluso-distal locations). The RBC specimens were then prepared as follows: EmbPol – tooth mold specimen was embedded in polystyrene resin and polished before testing; Pol – tooth mold specimen was not embedded, but was polished before testing; NotPol – sectioned tooth mold, specimen not embedded nor polished before testing. The KH was measured in different depths and regions of the specimens, and the DC was measured using Raman spectroscopy. Results The results were analyzed using a 2-way analysis of variance (ANOVA) or repeated measures followed by the Tukey post-hoc test (α=0.05). The preparation method (p<0.001), depth of restoration (p<0.001), and the interaction between method and depth (p=0.003) all influenced the KH values. Preparation method (p<0.001), tooth region (p<0.001), and the interaction between method and tooth region (p=0.002) all influenced DC values. The KH values were reduced significantly from the top to the bottom of the restorations and also at the proximal box when compared with the occlusal region. This outcome was most significant in the proximal boxes. The NotPol method was the most effective method to detect the effect of differences in KH or DC within the restoration. A lower DC and KH were found at the gingival regions of the proximal boxes of the restorations. When the KH and DC values were compared, there were no significant differences between the LCUs (KH p=0.4 and DC p=0.317). Conclusion Preparation methods that embedded the samples in polystyrene resin and polished the specimens reduced the differences between the KH and DC values obtained by different preparation techniques. The NotPol method was better able to detect differences produced by light activation in deeper areas.

Publisher

Operative Dentistry

Subject

General Dentistry

Reference50 articles.

1. Incremental filling technique and composite material-part I: cuspal deformation, bond strength, and physical properties;Bicalho;Operative Dentistry,2014

2. Resinas compostas suprananométricas proporcionando estética e função em dentes posteriores;Pupo;Journal of Clinical Dentistry & Research,2018

3. The effect of bulk depth and irradiation time on the surface hardness and degree of cure of bulk-fill composites;Farahat;Journal of Dental Biomaterials,2016

4. Impact of material shade and distance from light curing unit tip on the depth of polymerization of composites;Faria-e-Silva;Brazilian Dental Journal,2017

5. Effect of simulated pulpal microcirculation on temperature when light curing bulk fill composites;Braga;Operative Dentistry,2019

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3