Comparison of Blue and Infrared Light Transmission Through Dental Tissues and Restorative Materials

Author:

Pacheco RR1,Garcia-Flores AF2,Lesseux GG3,Lancelotti ACRA4,Rettori C5,Urbano RR6,Giannini M7,Rueggeberg FA8

Affiliation:

1. *Rafael Rocha Pacheco, DDS, MSc, PhD, Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, GA, USA

2. Ali Francisco Garcia-Flores, MSc, PhD, State University of Campinas, São Paulo, Brazil

3. Guilherme Gorgen Lesseux, MSc, PhD, State University of Campinas, São Paulo, Brazil

4. Ailla Carla Rocha Acosta Lancelotti, DDS, MSc, PhD, State University of Campinas, São Paulo, Brazil

5. Carlos Rettori, MSc, PhD, State University of Campinas, São Paulo, Brazil

6. Ricardo Rodrigues Urbano, MSc, PhD, State University of Campinas, São Paulo, Brazil

7. Marcelo Giannini, DDS, MSc, PhD, State University of Campinas, São Paulo, Brazil

8. Frederick Allen Rueggeberg, DDS, MS, Department of Restorative Sciences, The Dental College of Georgia at Augusta University, Augusta, GA, USA

Abstract

SUMMARY Objectives: The depth of cure using blue-light photocuring units (BL) is limited by tooth structure and qualities of the restorative material through which the activating wavelength must pass. Recent developments incorporate an infrared (IR) activated upconversion (UC) fluorescence of a lining agent filled with nanocrystals of NaYF4 and doped with YB+3 and Tm+3 that emit both blue and violet light locally at the interface of the liner and restorative resin. The purpose of this study was to evaluate the BL and 975 nm infrared (IR) light power transmission through dental tissues and restorative materials. Methods and Materials: Power transmissions of the IR laser (975 nm) and a monowave blue-only light-curing unit (Bluephase 16i) through dental tissues (enamel, dentin, and enamel/dentin junction, or DEJ), eight (8) various dental resin composites, and eight (8) dental ceramics, each at four thicknesses (1, 2, 3 and 4 mm) were evaluated (n=5) using a thermopile sensor (PM10, Coherent Inc) connected to a laser power meter (Fieldmate, Coherent Inc). Power transmission values of each light source and restorative material were subjected to analysis of variance and Tukey test at a pre-set alpha of 0.05. Results: A linear correlation (r=0.9884) between the supplied current and emitted IR power of the laser diode was found, showing no statistical power reduction with increased distances (collimated beam). For tooth tissues, the highest power transmissions for both light sources were observed using 1.0 mm enamel while the lowest values were found for 2.0 mm dentin and an association of 2.0 mm DEJ and 1.0 mm dentin. The only group where IR demonstrated significantly higher transmission when compared to BL was 1.0 mm enamel. For all resin composites and dental ceramics, increased thickness resulted in a reduction of IR power transmission (except for EverX Posterior fiber-reinforced composite and e.max HT ceramic). IR resulted in higher transmission through all resin composites, except for Tetric EvoCeram White. The highest BL transmission was observed for SDR Flow, at all thicknesses. Higher IR/BL ratios were observed for EverX Posterior, Herculite Ultra, and Lava Ultimate, while the lowest ratio was observed for Tetric EvoCeram White. Reduced translucency shades within the same material resulted in lower power ratio values, especially for BL transmission. Higher IR/BL ratios were observed for e.Max LT, VitaVM7 Base Dentin, and e.max CAD HT, while the lowest values were found for VitaVM7 Enamel and Paradigm C. Conclusion: IR power transmission through enamel was higher when compared to blue light, while no difference was observed for dentin. The power transmission of IR was higher than BL for resin composites, except for a high value and low chroma shade. Fiber-reinforced resin composite demonstrated the highest IR/BL power transmission ratio. A greater IR/BL ratio was observed for lower translucency ceramics when compared to high translucency.

Publisher

Operative Dentistry

Reference42 articles.

1. Resin composite--state of the art;Ferracane;Dental Materials,2011

2. State-of-the-art: Dental photocuring—a review;Rueggeberg;Dental Materials,2011

3. Light curing in dentistry and clinical implications: A literature review;Rueggeberg;Brazilian Oral Research,2017

4. Effect of high irradiance on depth of cure of a conventional and a bulk fill resin-based composite;AlQahtani;Operative Dentistry,2015

5. Curing dental resins and composites by photopolymerization;Stansbury;Journal of Esthetic and Restorative Dentistry,2000

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3