Debonding of Leucite-reinforced Glass-ceramic Veneers Using Er, Cr:YSGG Laser Device: Optimizing Speed with Thermal Safety

Author:

Walinski CJ,Gibson JE,Colvert DS,Redmond DC,Jafarian JH,Gregory PN,Ou KL

Abstract

Clinical Relevance Removing laminate veneers on anterior teeth by using an Er,Cr:YSGG dental laser can be completed faster than previously reported while maintaining thermal safety. SUMMARY Objective: When laminate veneer restorations require removal, the process is tedious, time-consuming, and potentially damaging to the underlying tooth structure. The purpose of this study was to evaluate the removal of Empress CAD milled laminate veneers on extracted human central incisors by using an Er,Cr:YSGG dental laser while optimizing speed and maintaining thermal safety. Methods and Materials: A total of 22 extracted human incisors were mounted in acrylic blocks. Conservative veneer preparations were made on all samples with a high-speed dental handpiece with a diamond bur and air/water spray. The 22 blocks of IPS Empress CAD were designed and milled into laminate veneers with a CAD/CAM System and luted to the prepared teeth. An Er,Cr:YSGG dental laser was fitted with a handpiece and laser fiber (600-μm diameter cylindrical fiber, 6 mm in length). Laser parameters were 333 mJ/pulse, 30 Hz, 80% air, 50% water, 600-μm diameter fiber tip, at a fluence of 885.96 J/cm2. The laser fiber tip was held directly on the surface of each veneer in contact, perpendicular to the surface, and moved slowly, covering the labial surface while firing. Results: At the laser parameters tested (333 mJ/pulse, 30 Hz, 80% air, 50% water, 600-μm diameter fiber tip), the average duration of exposure to completely remove each laminate veneer was 14.16 ± 0.60 seconds, with a range of 10.75 to 21.25 seconds. The average thickness of each veneer measured at the midfacial was 0.75 +/− 0.03 mm. The mean intrapulpal temperature increase for this period was 0.71°C ± 0.15°C. Conclusions: A regression model between time and thickness (p<0.0001) proved to be significant. However, the same cannot be said when the same modeling was tested between temperature and thickness. It can therefore be concluded that as the thickness of a veneer increases, more time is necessary to remove a veneer using Er,Cr:YSGG laser energy; however, increasing thickness does not necessarily result in an increase in pulpal temperature. Within the limitations of this study (single restorative material and single luting agent), it can be concluded that removing CAD Empress laminate veneer restorations using an Er,Cr:YSGG laser is reliable and thermally safe, even at an average of 10 W of power at 30 Hz. Additionally, thermal safety is maximized with adequate aerosolized water spray.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3