Influence of Light-curing Parameters on Biofilm Development and Flexural Strength of a Silorane-based Composite

Author:

Brambilla E1,Ionescu A2,Cazzaniga G3,Ottobelli M1

Affiliation:

1. Eugenio Brambilla, DDS, IRCCS Galeazzi Institute, University of Milan, Department of Biomedical, Surgical and Dental Sciences, Milan, Italy

2. Andrei Ionescu, DDS, PhD, IRCCS Galeazzi Institute, University of Milan, Department of Biomedical, Surgical and Dental Sciences, Milan, Italy

3. Gloria Cazzaniga, DDS, IRCCS Galeazzi Institute, University of Milan, Department of Biomedical, Surgical and Dental Sciences, Milan, Italy

Abstract

SUMMARYObjectives: The aim of this study was to evaluate the differences in biological and mechanical performances of a silorane-based and a methacrylate-based composite. Another aim was to assess the influence of light-curing time and light-curing intensity on in vitro biofilm formation and flexural strength of the two tested composites.Methods: Experiment 1: 432 specimens obtained from a silorane-based composite and from a standard methacrylate-based composite were divided into six groups and light-cured for 10, 20, 30, 40, 60, or 80 seconds, using one of two light-curing intensities, 400 mW/cm2 or 800 mW/cm2. At 24 hours, a monospecific Streptococcus mutans biofilm adherent to the surfaces of the samples was obtained. Then, a colorimetric technique (MTT assay) was used to evaluate the adherent viable biomass. Two samples per group were observed using confocal laser scanning microscopy. Analysis of variance (ANOVA) and Tukey tests were used to analyze the results (p<0.05). Experiment 2: 192 bar-shaped specimens were obtained and light-cured as in the previous experiment. A three-point bend test using a universal testing machine was performed to obtain flexural strength values. ANOVA and Tukey tests were used to analyze the results (p<0.05).Results: In experiment 1, a highly significant difference (p<0.0001) in biofilm development was shown between silorane-based and methacrylate-based composites. In fact, the silorane-based composite exhibited better biological performance. Significant differences were also found between the two light-curing intensities (p<0.018) and for curing times (p<0.0001): silorane-based composite light-cured for 80 seconds at 800 mW/cm2 light-curing intensity showed the lowest biofilm development. In experiment 2, a significant difference in flexural strength (p<0.0318) was only found between the different composites. Nevertheless, both resin composites showed flexural strength values in accordance with International Organization for Standardization guidelines even after 10 seconds of light-curing time.Conclusions: Silorane-based composite was less prone to biofilm development compared with a methacrylate-based composite. Acceptable flexural strength values for both composites were obtained after 10 seconds of light-curing time.

Publisher

Operative Dentistry

Subject

General Dentistry

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3