Does a Self-etching Ceramic Primer Improve Bonding to Lithium Disilicate Ceramics? Bond Strengths and FESEM Analyses

Author:

Lopes GC1,Perdigão J2,Baptista D3,Ballarin A4

Affiliation:

1. Guilherme Carpena Lopes, DDS, MS, PhD, Department of Operative Dentistry, CCS/ODT, Campus Universitário Trindade, Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil

2. Jorge Perdigão, DMD, MS, PhD, Department of Restorative Sciences, University of Minnesota, Minneapolis, MN, USA; Visiting Professor, Faculty of Dental Medicine, University of Lisbon, Lisbon, Portugal

3. Daniel Baptista, DDS, MS, PhD candidate, Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil

4. Andressa Ballarin, DDS, Laboratório Central de Microscopia Eletrônica, Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil

Abstract

SUMMARY Objective: To compare the effect of hydrofluoric acid (HF) vs self-etching ceramic primer on resin cement microshear bond strength (μSBS) and ultramorphology of lithium disilicate (LD) ceramic. Methods and Materials: LD (IPS e.max CAD, Ivoclar Vivadent) blocks (14×4×2 mm3) were polished to 1200 grit and assigned to nine groups (n=5): CON: control, no LD surface treatment; IVO: 5.0% HF (IPS Ceramic Etching Gel, Ivoclar Vivadent); VIT: 5.0% HF (Vita Ceramics Etch, VITA Zahnfabrik); FGM: 5.0% HF (Condac Porcelana, FGM); ULT: 9.0% HF (Porcelain Etch, Ultradent); PRM: 9.6% HF (Premier Porcelain Etch Gel, Premier); BIS: 9.5% HF (Porcelain Etchant, Bisco Inc); DEN: 10.0% HF (Condicionador de Porcelanas, Dentsply Brazil); and MEP: self-etching ceramic primer (Monobond Etch & Prime, Ivoclar Vivadent). For all HF groups and control, an MDP-containing silane solution (MB+, Monobond Plus, Ivoclar Vivadent) was applied on rinsing the HF gel and air drying. Three transparent matrices for each specimen were filled with light-cured resin cement (Variolink Veneer, Ivoclar Vivadent). After storage in water for 48 hours at 37°C, specimens were tested in shear mode to measure μSBS. Mode of failure was analyzed at 50×. Statistical analysis included one-way analysis of variance and the Duncan post hoc test (α=0.05). Thirty-six additional LD specimens were assigned to the same experimental groups (n=4) and observed under a field-emission scanning electron microscope (FESEM) at magnifications ranging from 10,000× to 100,000×. Results: IVO resulted in statistically higher mean μSBS than all the other groups. MEP resulted in statistically lower μSBS than all HF groups. The failure mode for MEP was predominantly adhesive. The most frequent failure mode for the HF groups was mixed. CON resulted in 100% pretesting failures. For FESEM, no retentive pattern was observed for CON specimens. MEP resulted in the least pronounced etching pattern, few areas around crystals exhibited a slight increase in retention pattern compared to the control group. All HF gels created microporosities on the LD surface with distinct etching patterns. VIT and DEN resulted in an LD ultramorphology that suggested overetching. Conclusions: HF etching followed by a silane solution resulted in higher bond strengths than a self-etching ceramic primer. Some HF gels may cause overetching of the LD intaglio surface.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3