Effect of High-radiant Emittance and Short Curing Time on Polymerization Shrinkage Vectors of Bulk Fill Composites

Author:

Hirata R1,Sampaio CS2,Atria PJ3,Giannini M4,Coelho PG5,Yamaguchi S6

Affiliation:

1. Ronaldo Hirata, DDS, MS, PhD, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY USA

2. *Camila S Sampaio, DDS, MD, PhD, Department of Biomaterials, School of Dentistry, Universidad de los Andes, Santiago, Chile

3. Pablo J Atria, DDS, MS, Department of Biomaterials, School of Dentistry, Universidad de los Andes, Santiago, Chile

4. Marcelo Giannini, DDS, MS, PhD, Department of Restorative Dentistry, Operative Dentistry Division, University of Campinas, Piracicaba Dental School, Piracicaba, Brazil

5. Paulo G. Coelho, DDS, MS, PhD, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY

6. Satoshi Yamaguchi, DDS, MS, PhD, Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Osaka, Japan

Abstract

SUMMARY Purpose To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. Methods and Materials Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0–4 mm): top, top-middle, middle, middle-bottom and bottom. Results TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). Conclusions Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.

Publisher

Operative Dentistry

Subject

General Dentistry

Reference37 articles.

1. Resin composite—state of the art;Ferracane;Dental Materials,2011

2. Cusp reinforcement by the acid-etch technique;Morin;Journal of Dental Research,1984

3. Composite polymerization stress as a function of specimen configuration assessed by crack analysis and finite element analysis;Braga;Dental Materials,2013

4. A review of polymerization contraction: The influence of stress development versus stress relief;Carvalho;Operative Dentistry,1996

5. Margin analysis of posterior composites in vivo;Roulet;Dental Materials,1991

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3