Complications of appendicular fracture repair in cats and small dogs using locking compression plates

Author:

Le Pommellet Helene,Savin Audrey,Decambron Adeline,Manassero Mathieu,Viateau Véronique,Gauthier Olivier,Fayolle Pascal,Vallefuoco Rosario

Abstract

SummaryObjective: Our objectives were: 1) to review the complications associated with stabilization of appendicular fractures in cats and small dogs using locking compression plates (LCP), and 2) to identify factors that could influence fixation construct stability.Study design: Retrospective clinical study.Materials and methods: Medical and radiographic records of cats and small dogs with appendicular fractures treated with LCP were reviewed. Only cases with adequate follow-up to document clinical union and cases for which complications appeared before the clinical union were included. Complications were classified as implant-related complications or other complications. Cases with implant-related complications were compared to cases with non-implant-related complications for differences in signalment (species, age, body weight, multiple fractures), fracture location and type (fractured bone, fracture localization, closed or open fracture), reduction method (open reduction and internal fixation [ORIF] or minimally invasive plate osteosynthesis [MIPO]) and fixation evaluations (implant size, platebridging ratio, plate span ratio, working length, plate screw density, number of screws and cortices engaged per plate and per main fragment, ratio between screw and bone diameter at the narrowest aspect of the bone, and presence of ancillary fixation).Results: Seventy-five fractures from 63 cats (64 fractures) and 10 dogs (11 fractures) met the inclusion criteria. Eight humeral, 13 radio-ulnar, 26 femoral, and 28 tibio-fibular fractures were treated. Primary repair of the fracture was performed using 2.0 mm and 2.4 mm LCP in 22 and 53 fractures, respectively. Overall and implant-related complications were encountered in 13 and seven of 75 fractures, respectively. Fixation failure was not significantly associated with any aforementioned factor considered in this study, and in particular, there was no significant difference in the occurrence of fixation failure between fractures stabilized with two, or more than two, bicortical locking screws per main fragment.Clinical significance: 2.0 mm and 2.4 mm LCP were used to manage appendicular fractures in cats and small dogs. The overall complication and fixation failure rate were comparable to those reported in previous studies in which various locking plate systems were used.Online Supplementary Material for this article is available at: http://dx.doi.org/10.3415/VCOT-14-09-0146

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3