Cystoscopic-guided scissor transection of intramural ectopic ureters as a novel alternate minimally invasive treatment option to laser ablation in female dogs: 8 cases (2011–2020)

Author:

Jacobson Else1,Meler Erika N.2,Delisser Peter J.3,Thompson Ann L.1

Affiliation:

1. Internal Medicine Department, Veterinary Specialist Services, Underwood, QLD, Australia

2. Small Animal Medicine Department, School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia

3. Surgery Department, Veterinary Specialist Services, Underwood, QLD, Australia

Abstract

Abstract OBJECTIVE To evaluate the safety and efficacy of cystoscopic-guided scissor transection of ectopic ureters (CST-EU) in female dogs. ANIMALS 8 incontinent female dogs with intramural ectopic ureters. PROCEDURES For this retrospective case series, data were collected from medical records of dogs that underwent CST-EU to relocate the ectopic ureteral orifice to an anatomically normal trigonal location between June 2011 and December 2020. Outcome after hospital discharge was determined using owner telephone questionnaires. RESULTS Ectopic ureters were bilateral in 4 of the 8 dogs, and all dogs had other urogenital tract anomalies. Owner questionnaire follow-up was available for 7 dogs, and results indicated 6 dogs had improved urinary continence immediately following the procedure. At the last follow-up (44 to 3,384 days after CST-EU), 3 of the 7 dogs were completely continent with CST-EU alone, 3 others became continent or were markedly improved with the addition of medications for urethral sphincter mechanism incompetence, and 1 required ureteroneocystostomy, colposuspension, and an artificial urethral sphincter to become fully continent. Owners of 5 of the 7 dogs reported that they considered the outcome of CST-EU as good to excellent, and all owners reported that they would consider having CST-EU performed again should they have another incontinent dog. Complications were minor, and only 3 dogs showed transient lower urinary tract signs after CST-EU. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated CST-EU could provide a safe, effective, minimally invasive alternative in the absence of laser technology for the treatment of intramural ectopic ureters in female dogs.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary

Reference27 articles.

1. Canine ureteral ectopia–a review 1. Embryology and aetiology;Owen RR,1973

2. Ureteral ectopia and urethral sphincter mechanism incompetence: an update on diagnosis and management options;Owen LJ,2019

3. Urinary incontinence in dogs and cats;Holt PE,1990

4. Canine ureteral ectopia: an analysis of 175 cases and comparison of surgical treatments;Holt PE,1995

5. Surgery of ectopic ureters- types, method of correction, and postoperative results;Stone EA,1990

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3