Biomechanical evaluation of locking versus nonlocking 2.0-mm malleable L-miniplate fixation of simulated caudal mandibular fractures in cats

Author:

Kot Ching Ching Shirley1,Verstraete Frank J. M.2,Garcia Tanya C.23,Stover Susan M.23,Arzi Boaz23

Affiliation:

1. Dentistry and Oral Surgery Service, William R. Pritchard Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California-Davis, Davis, CA

2. Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, CA

3. J.D. Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California-Davis, Davis, CA

Abstract

Abstract OBJECTIVE To evaluate the biomechanical properties of the mandibles of cats with experimentally created osteotomies simulating oblique ramus fractures, which were stabilized with malleable L-miniplates with either locking screws [locking construct (LC)] or nonlocking screws [nonlocking construct (NLC)], compared with those for intact mandibles. SAMPLES 20 mandibles from 10 adult cat cadavers. PROCEDURES A block study design was adopted to allocate the mandibles of each cadaver to 2 of the 3 test groups (LC, NLC, or intact mandible). Mandibles within each cadaver were allocated systematically to a test group. For mandibles assigned to an LC and an NLC, a complete oblique osteotomy was performed from the mid rostral aspect of the ramus in a caudoventral direction. All mandibles were loaded in a single-load-to-failure test through cantilever bending. Load and actuator displacement were recorded simultaneously. Mode of failure and radiographic evidence of damage to tooth roots and the mandibular canal were evaluated. Biomechanical properties were compared among the groups. RESULTS No iatrogenic tooth root damage was evident, but all mandibles with an LC and an NLC had evidence of screw invasion into the mandibular canal. Plated mandibles had significantly less stiffness and bending moment than intact mandibles. Stiffness was not significantly different between the LC and the NLC; the NLC had a greater bending moment at failure than the LC. The pre-yield stiffness of plated mandibles decreased when the number of screw holes overlapping the mandibular canal increased. CLINICAL RELEVANCE The use of a malleable L-miniplate in a caudal mandibular fracture model is feasible. Both the LC and the NLC were inferior mechanically to intact mandibles. Type of construct used did not affect the construct stiffness significantly in tested mandibles.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Reference46 articles.

1. A survey of bone fractures in the cat,1977

2. A survey of bone fractures in the dog and cat,1979

3. Mandibular fractures in the cat: a retrospective study,1988

4. A survey of fractures in the dog and cat in Malaysia,1984

5. Feline head trauma: a CT analysis of skull fractures and their management in 75 cats,2019