A clinically utilized intravenous continuous rate infusion of diltiazem does not significantly decrease systolic function in healthy dogs

Author:

Whitehouse William H.1,Thomason Justin D.1,Thompson-Butler Dorothy A.1,Kelley Megan D.1,Cernicchiaro Natalia2,Tanner Matthew C.1

Affiliation:

1. Department of Clinical Sciences, College of Veterinary Medicine, Kansas State University, Manhattan, KS

2. Center for Outcomes Research and Epidemiology and Department of Diagnostic Medicine/Pathobiology, College of Veterinary Medicine, Kansas State University, Manhattan, KS

Abstract

Abstract OBJECTIVE To determine if left ventricular systolic function on echocardiography, systemic blood pressure, and electrocardiography change with a clinically accepted intravenous (IV) diltiazem constant rate infusion (CRI) compared to a control. ANIMALS 10 healthy client-owned adult dogs. PROCEDURES Prospective, masked, crossover study from May 27, 2021, to August 22, 2021. Dogs were randomized to receive diltiazem (loading dose of 240 μg/kg, IV followed by a CRI of 6 μg/kg/min for 300 minutes) or the same volume of 5% dextrose in water (D5W) administered IV followed by the opposite intervention after a 7-day washout. Blood pressure was monitored during each CRI, and echocardiographic and electrocardiographic studies were performed immediately before the CRI and during the last hour of the CRI. RESULTS Postdiltiazem systolic time interval (STI) (median, 0.30; range, 0.16 to 0.34) was significantly lower than post-D5W STI (median, 0.32; range, 0.22 to 0.40; P = .046). All other echocardiographic parameters did not differ significantly between each of the groups after receiving diltiazem or D5W. Systemic blood pressure did not change significantly with either diltiazem (P = .450) or D5W (P = .940), and none of the dogs became hypotensive at any point in the study. Expectedly, negative dromotropy was observed with diltiazem. CLINICAL RELEVANCE A significant decrease in left ventricular systolic function was not appreciated in healthy dogs receiving diltiazem at a clinically accepted intravenous infusion rate at this dosing regimen. Further studies are needed in dogs with cardiac disease.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine