X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders during diagnostic radiographic procedures of the equine vertebral column and limbs

Author:

Belotta Alexandra F.1,Mayer Monique N.1,Waldner Cheryl L.2,Sidhu Narinder P.3,Robinson Kate A.2,Carmalt James L.2,Freitas Fernando P.1,Koehncke Niels K.4

Affiliation:

1. Department of Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada

2. Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada

3. British Columbia Cancer, Prince George, BC, Canada

4. Department of Medicine, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada

Abstract

Abstract OBJECTIVE The objectives of this study were to investigate scattered radiation doses to the hands of equine workers holding the cassette and the x-ray tube by hand, for both limb and vertebral column studies, and to compare the scattered radiation attenuation of lead with radiation protection lead-free gloves. Radiation doses to the hands of the cassette holder in the primary beam were also investigated. SAMPLE A whole-body horse cadaver. PROCEDURES A portable x-ray unit was used to simulate 6 radiographic study types in the horse cadaver. Doses were measured with no shielding and, for cassette holders, with the ion chamber enclosed in a lead glove and a lead-free glove. Thirty exposures were performed for each study view and condition (n = 1,920). RESULTS Mean scattered doses to x-ray unit operators were higher than doses to cassette holders for ungula (hoof), thoracic vertebrae, and lumbar vertebrae studies, whereas doses to cassette holders were higher than doses to x-ray tube operators for studies of the metacarpophalangeal joint (fetlock) and tarsus (hock). Doses did not differ for the stifle joint. Mean percentage decrease in scattered radiation dose was 99.58% with lead gloves and 98.9% with lead-free gloves. CLINICAL RELEVANCE X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders. Lead-free hand shielding should only be considered as an alternative to lead gloves if their lighter weight increases frequency of use by workers.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3