Keratometry, biometry, and prediction of intraocular lens power in adult tigers (Panthera tigris)

Author:

Owens Cameron D.1,Michau Tammy M.12,Boorstein Justin3,Wynn Elizabeth R.3,McMullen Richard J.4

Affiliation:

1. 1Blue Pearl Veterinary Partners, Tampa, FL

2. 2Mars Veterinary Health, Vancouver, WA

3. 3Big Cat Rescue, Tampa, FL

4. 4Department of Veterinary Ophthalmology, JT Vaughan Large Animal Teaching Hospital, College of Veterinary Medicine, Auburn University, Auburn, AL

Abstract

Abstract OBJECTIVE To calculate the necessary pseudophakic intraocular lens (IOL) power to approximate emmetropia in adult tigers. ANIMALS 17 clinically normal adult tigers. PROCEDURES 33 eyes of 17 clinically normal adult tigers underwent routine ophthalmic examination and B-scan ultrasonography while anesthetized for unrelated procedures. Specific ultrasound data (globe measurements and corneal curvature) and estimated postoperative IOL positions were utilized to calculate predicted IOL power by use of Retzlaff and Binkhorst theoretical formulas. Applanation tonometry and refraction were also performed. RESULTS Mean ± SD axial globe length was 29.36 ± 0.82 mm, preoperative anterior chamber depth was 7.00 ± 0.74 mm, and crystalline lens thickness was 8.72 ± 0.56 mm. Mean net refractive error (n = 33 eyes) was +0.27 ± 0.30 diopters (D). By use of the Retzlaff formula, mean predicted IOL power for the postoperative anterior chamber depth (PACD), PACD – 2 mm, and PACD + 2 mm was 43.72 ± 4.84 D, 37.62 ± 4.19 D, and 51.57 ± 5.72 D, respectively. By use of the Binkhorst equation, these values were 45.11 ± 4.91 D, 38.84 ± 4.25 D, and 53.18 ± 5.81 D, respectively. Mean intraocular pressure for all eyes was 14.7 ± 2.69 mm Hg. CLINICAL RELEVANCE The calculated tiger IOL was lower than reported values for adult domestic felids. Further studies evaluating actual PACD and pseudophakic refraction would help determine the appropriate IOL power to achieve emmetropia in this species.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Reference92 articles.

1. Refractive states of eyes and associations between ametropia and age, breed, and axial globe length in domestic cats;Konrade;Am J Vet Res.,2012

2. Use of biometry and keratometry for determining optimal power for intraocular lens implants in dogs;Gaiddon;Am J Vet Res.,1991

3. Phacoemulsification and intraocular lens implantation in dogs: a study of technique in 182 dogs;Nasisse;Prog Vet Comp Ophthalmol.,1991

4. The allometry and scaling of the size of vertebrate eyes;Howland;Vision Res.,2004

5. Assessment of corneal thickness, intraocular pressure, optical corneal diameter, and axial globe dimensions in Miniature Horses;Plummer;Am J Vet Res.,2003

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Congenital glaucoma in a tiger (Panthera tigris);Veterinary Ophthalmology;2023-05-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3