Point-of-care ketone meters may be used to estimate serum β-hydroxybutyrate concentrations in healthy African penguins (Spheniscus demersus)

Author:

Meade Sharonda M.1,Di Girolamo Nicola2,Cray Carolyn3,Aquilino Nicolette4,DiGeronimo Peter M.45,Brandão João2

Affiliation:

1. Animal and Bird Health Care Center, Cherry Hill, NJ

2. Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK

3. Department of Pathology and Laboratory Medicine, University of Miami, Miami, FL

4. Adventure Aquarium, Camden, NJ

5. Philadelphia Zoo, Philadelphia, PA

Abstract

Abstract OBJECTIVE To evaluate the agreement between 3 point-of-care (POC) devices and a reference laboratory for measuring β-hydroxybutyrate (β-HB) concentration in African penguin (Spheniscus demersus) whole blood (WB) and plasma samples and the precision of each POC device for measuring β-HB concentration in plasma samples. ANIMALS 48 healthy African penguins. PROCEDURES Blood was obtained from the right jugular vein of each penguin, and β-HB concentration was measured on each POC device using fresh WB and heparinized plasma and at the reference laboratory using plasma. β-HB concentration was measured in plasma on each POC device. RESULTS All devices overestimated serum β-HB concentrations on average by 0.46 mM relative to the reference laboratory. WB samples had less error than plasma for meters A and C. Meter A had the lowest total error observed (26.4%) and the lowest mean difference (0.19 mmol/L) relative to the reference laboratory. Controlling for other factors, the magnitude of disagreement was not affected by sex, age, packed cell volume, or serum total solids concentration. CLINICAL RELEVANCE WB, not plasma, should be used for measurement of β-HB concentration on the POC meters tested. Meter A showed good correlation with the reference laboratory for WB. The use of POC devices for the measurement of β-HB concentration may be acceptable when laboratory analyzers are not available. Further research is needed for clinical application and the diagnostic value of POC meters compared with reference laboratories.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3