Abstract

Abstract OBJECTIVE To compare single and triplicate applanation tonometry values across previous intraocular pressure (IOP) studies in dogs. ANIMALS 116 ophthalmologically normal dogs. PROCEDURES Triplicate IOP readings (n = 1432) from studies evaluating effect of anesthetic protocols were analyzed to estimate a range of probable differences between averaged triplicate and first, averaged and lowest, and first and lowest IOPs. The decrease in variability with triplicate measurements and the magnitude of effects on statistical power were quantified. RESULTS The 2.5th to 97.5th interpercentile range for differences of averaged triplicate values minus first IOP readings was –3 to 2.7 mm Hg; for averaged minus lowest: 0 to 3.7 mm Hg; for first minus lowest: 0 to 5 mm Hg. The 95% prediction interval for differences in study group means (n = 160 groups, n = 5 to 11 eyes per group) based on averaged minus first measurements was –1.0 to 0.9 mm Hg with associated SDs reduced by 4% on average. Analysis of previous studies using averaged instead of first IOP values resulted in minimal decreases in SEs of 3–9% (0.03 to 0.09 mm Hg). Of 11 comparisons found significant with averaged data, 2 (18%) were found nonsignificant with first measurements. Of 96 comparisons found nonsignificant with averaged data, 3 (3%) were found significant with first measurements. CLINICAL RELEVANCE With applanation tonometry in ophthalmologically normal dogs, no clinically meaningful difference was found between the first, lowest, or averaged triplicate IOP measurements, but the first reading has a larger variance and hence will result in lower statistical power.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3