A flexible endotracheal tube introducer improves first-attempt success of intubation in cats by novice anesthetists

Author:

Martin-Flores Manuel1,Sakai Daniel M.2,Muto Richard Marra3,Burns Charlotte C.4,Araos Joaquin D.1,de Miguel Garcia Cristina1,Campoy Luis1

Affiliation:

1. Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY

2. Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA

3. Cornell University Hospital for Animals, College of Veterinary Medicine, Cornell University, Ithaca, NY

4. Department of Large Animal Medicine, College of Veterinary Medicine, University of Georgia, Athens, GA

Abstract

Abstract OBJECTIVE To test whether the use of a flexible endotracheal tube introducer (ETI) facilitates intubation of cats by veterinary students with little or no experience. ANIMALS 125 healthy cats. PROCEDURES Cats were sedated with dexmedetomidine and morphine IM, and anesthesia was induced with propofol. They were randomly assigned to be intubated by supervised veterinary students using an ETI within a tracheal tube or an endotracheal tube alone (3.0, 3.5, or 4.0 internal diameter sizes). Success rate at first attempt, number of attempts to intubate (up to 3), and time to intubate were recorded. Multivariate logistic regression was used to test associations between several factors such as use of an ETI, cat’s weight, endotracheal tube size, administration of ketamine for sedation, and first-attempt success. Significance was considered when P < 0.05. RESULTS Success rate for the first attempt was higher with an ETI (79% [51/64) than without it (46% [28/61]), and attempts to intubate were fewer when an ETI was used (both P < 0.001). Time to intubate did not differ between groups (ETI, 30 seconds [4 to 143 seconds]; endotracheal tube, 28 seconds [5 to 180 seconds]). Use of an ETI was positively associated with improved first-attempt success, and the 3.0-mm internal diameter of the tube was negatively associated (both P ≤ 0.001). CLINICAL RELEVANCE The use of a flexible ETI improved the success of first-attempt intubation of cats by veterinary students. This technique may help minimize the number of attempts during intubation and incidence of complications that could arise from multiple attempts.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3