Comparison of four endotracheal tube cleaning protocols in anesthetized dogs

Author:

Marquis Charlotte R.1,Gull Tamara2,Dodam John1,Thombs Lori3,Bukoski Alex1

Affiliation:

1. Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO

2. Veterinary Medical Diagnostic Laboratory, College of Veterinary Medicine, University of Missouri, Columbia, MO

3. Department of Statistics, College of Arts and Sciences, University of Missouri, Columbia, MO

Abstract

Abstract OBJECTIVE To compare the efficacy of 4 cleaning protocols applied to endotracheal tubes (ETTs) collected from anesthetized dogs. SAMPLE 100 ETTs (25 per protocol). PROCEDURES A 10-question survey designed to determine ETT reuse and cleaning practices was distributed via email to a sample of veterinary anesthesiologists. Informed by survey results, 4 ETT cleaning protocols were selected for use in a prospective clinical study. Dogs were intubated with sterile polyvinyl chloride ETTs. At extubation, each ETT was cultured for bacterial growth, randomly assigned to 1 of 4 protocols [water scrub (P1), detergent scrub (P2), detergent scrub and chlorhexidine gluconate (CHG) soak (P3), or detergent scrub and bleach soak (P4)], and cultured again after drying. Bacterial genera were identified using mass spectrometry and 16s rRNA sequencing. Proportions of ETTs exhibiting no post-cleaning growth were compared between protocols using the Fisher exact test with Bonferroni correction. RESULTS Half of survey respondents that reused ETTs did not sterilize them before reuse, cleaning methods varied widely, and no reported methods were evidence-based. After use, the number of ETTs exhibiting no post-cleaning bacterial growth were 15/25 (60%), 14/25 (56%), 20/25 (80%), and 17/25 (68%) for protocols P1, P2, P3, and P4, respectively. Pairwise comparisons did not reveal any statistically significant differences between protocols. CLINICAL RELEVANCE In small animal patients, some veterinary anesthesiologists reuse ETTs without sterilization and cleaning protocols vary widely. No differences between the studied protocols were identified. Further research is necessary to identify a safe, efficacious ETT cleaning protocol for use in small animal practice.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary

Reference13 articles.

1. Technical standards for tracheal tubes;Colice GL,1991

2. Update on acquired immune deficiency syndrome (AIDS)—United States,1982

3. Tracheal and nasal intubation;Bednarski RM,2009

4. Cleaning and sterilisation of anaesthetic equipment;Juwarkar CS,2013

5. Decontamination of anaesthetic equipment and ventilators;Lumley J.,1976