Affiliation:
1. Department of Power Electronics and Motor Xi'an University of Technology Xi'an China
2. Department of Electrical and Electronic Engineering University of Nottingham Nottingham UK
Abstract
AbstractThe model‐based sensorless control of permanent magnet synchronous motor (PMSM) relies on the motor parameters. In practice, the considerable uncertainty of inductance and the difference between the apparent inductance and the incremental inductance exists. To overcome it, an online apparent inductance identification method for PMSM sensorless control is proposed. First, an initial incremental inductance table (IIT) is obtained offline. Then, an asymmetric high‐frequency square wave injection method is proposed to identify the incremental inductance at the operation point, and an adaptive minimum adjustment algorithm is proposed to adjust IIT automatically. Finally, the apparent inductance is calculated using the adjusted IIT. Based on it, the complete PMSM sensorless control is designed. The experimental results indicate this method is feasible and effective.
Funder
National Natural Science Foundation of China
Natural Science Basic Research Program of Shaanxi Province
Postdoctoral Research Foundation of China
Publisher
Institution of Engineering and Technology (IET)