Affiliation:
1. School of Automation and Electrical Engineering Lanzhou Jiaotong University Lanzhou China
Abstract
AbstractWith the penetration of the high proportion of power electronics interfaced energy resources, the frequency stability issue in power systems is becoming increasingly prominent. This paper proposes a coordinated control strategy of multiple voltage source converter based high voltage direct current transmission (VSC‐HVDC) to simultaneously improve the transient frequency and steady‐state frequency after a severe disturbance. Firstly, a modified average system frequency response (MASFR) model is constructed with reserve power limitation, which takes into account the frequency responses of different types of generators (thermal, hydro and new energy resources). Secondly, according to the frequency stability requirements, the corresponding constraints, which consider the overload capacity of VSC‐HVDC, the AC transmission capacity and the frequency of AC grids on both sides of VSC‐HVDC, are formulated. Thirdly, for the transient frequency control, the coordinated optimization control model of multiple VSC‐HVDC is established, which aims to minimize the control energy considering the transient frequency threshold. For the steady‐state frequency control, the coordinated optimization control model is fomulated, which aims to minimize the control cost while considering the steady‐state frequency threshold. The two control schemes achieve seamless and smooth switching. Finally, the correctness and effectiveness of the proposed control strategy are verified in the improved IEEE 39 bus system.
Publisher
Institution of Engineering and Technology (IET)
Reference39 articles.
1. Key technologies and developing challenges of power system with high proportion of renewable energy;Zhuo Z.;Autom. Electr. Power Syst.,2021
2. Milano F. Dörfler F. Hug G. et al.:Foundations and challenges of low‐inertia systems. In:2018 Power Systems Computation Conference pp.1–25.Dublin Ireland(2018)
3. Inertia response and frequency control techniques for renewable energy sources: A review
4. Analysis and reflection on frequency characteristics of east china grid after bipolar locking of “9·19” Jinping‐Sunan DC transmission line;Li Z.;Autom. Electr. Power Syst.,2017
5. AEM Operator:Black System South Australia 28 September 2016‐Final Report. Australian Energy Market Operation Limited. Australia.http://www.aemo.com.au/‐/media/Files/Electricity/NEM/MarketNoticesandEvents/PowerSystemIncidentReports/2017/Integrated‐Final‐Report‐SA‐Black‐System‐28‐Septe‐mber‐2016.pdf(2017)