Time domain response of corrugated transmission lines

Author:

Wu Chia Ho1ORCID,Wang Wei1,Peng Song Tsuen2,Qian Zhenyu1,Shen Jianqi3,Ye Guoqiang4,Ni Donghua4,He Fang4,Shen Linfang1,Quan Bisheng1,Jiao Yajie5

Affiliation:

1. Department of Applied Physics College of Science Zhejiang University of Technology Hangzhou China

2. Department of Electrical Engineering National Yang Ming Chiao Tung University Hsinchu Taiwan

3. Centre for Optical and Electromagnetic Research College of Optical Science and Engineering Zhejiang University Hangzhou China

4. Zhejiang Zhaolong Interconnect Technology Co., Ltd. Huzhou China

5. Cosine Technology Co., Ltd. Xiamen China

Abstract

AbstractIn order to employ periodic corrugated microstrip lines for reducing or suppressing electromagnetic interference in high‐speed or high‐frequency circuits, a precise method is necessary to calculate and measure the characteristic impedance of periodic microstrip lines. The equation for characteristic impedance (depending on frequency) of lossless periodic microstrip lines was obtained based on the transfer matrix method. A time domain pulse was used to measure the instantaneous impedance of conventional microstrip lines, and when the instantaneous impedance does not change with distance, it can be identified as the characteristic impedance of microstrip lines. However, when the time‐domain pulses are employed to measure the instantaneous impedance of periodic microstrip lines, rapid oscillations occur with distance. Therefore, a standard for spacing between adjacent grooves in the microstrip line can be suggested by analysing the interaction between the time‐domain pulses and the microstrip line grooves. Once such a standard is satisfied, many grooves etched along the microstrip line would no longer be distinguished by the time‐domain pulses. Such a principle and method can be used to determine the instantaneous impedance for the microstrip lines that have periodic grooves. On the other hand, when several periodic structures with different lattice constants coexist on a microstrip line, they can also be distinguished via the instantaneous impedance. A time domain reflectometer was used for measuring the instantaneous impedance of periodic microstrip lines, and the measured results are in agreement with the theoretical analysis.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Zhejiang Province

Publisher

Institution of Engineering and Technology (IET)

Subject

Electrical and Electronic Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3