Assessing the safety of interrogating cardiac-implantable electronic devices with brand-mismatched remote interrogators: a pilot study

Author:

Le TinhORCID,Neuenschwander James,Cordial Parker,Sankoe Mackenzie,Parekh Ankur,Hiestand Brian,Peacock WF

Abstract

Objective Remote cardiac implantable electronic device (CIED) interrogators, originally developed for home use, have been proven to be efficacious in clinical settings, especially emergency departments. Concern exists that attempting to interrogate a CIED with the remote interrogator of a different brand, i.e., a brand-mismatched interrogator, may cause device malfunction. The aim of this study was to determine if intentionally attempting to interrogate a CIED with a brand-mismatched remote interrogator resulted in device malfunction.Methods A total of 75 ex vivo CIEDs manufactured by various companies underwent attempted interrogation by a brand-mismatched remote interrogator. CIED settings were compared before and after attempted mismatch interrogation. A total of 30 in vivo CIEDs were then randomized for an attempted 2-minute mismatched remote interrogation by one of the two possible mismatched remote interrogators. CIED settings were compared before and after attempted mismatch interrogation.Results Of 150 ex vivo brand-mismatched interrogations, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices were turned off. In the 30 patients undergoing brand-mismatched interrogations, the mean (standard deviation) age was 71.6 ( ± 14.7) years, 16 (53%) were male, with 24 pacemakers (80%), four pacemaker/implantable cardioverter defibrillators (13%), and two implantable cardioverter defibrillators (7%). Of the 30 mismatched interrogations performed, no device setting changes or malfunctions occurred; no remote interrogators connected to a mismatched CIED, and no devices turned off.Conclusion In a total 180 attempted brand-mismatched CIED interrogations, no CIED malfunctions occurred. This suggests that the use of remote CIED interrogators when device manufacturer is unknown is unlikely to result in adverse CIED-related events.

Publisher

The Korean Society of Emergency Medicine

Subject

Emergency Nursing,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3