Application of different metrics for describing light color quality of white LED

Author:

Supronowicz Robert,Fan Jiajie,Listowski Maciej,Watras Adam,Fryc Irena

Abstract

Using the example of the UV-excited Ca9KMg(PO4)7:1% Eu2+ phosphor, methods for characterizing the color quality of the light emitted by it at different operating temperatures are described. The effect of adopting two different colorimetric observers established by the International Commission on Illumination (i.e., the CIE 1931 observer with a viewing angle of two degrees and the CIE 2015 observer with a viewing angle of ten degrees) on the position of the chromaticity point of light emitted by phosphor is discussed. It was demonstrated that using the CIE 2015 photometric observer to determine the position of the chromaticity point, the tested phosphor is characterized by smaller changes in the color of emitted light as a function of operating temperature than when using the CIE 1931 observer. Full Text: PDF ReferencesR. Pązik et al., "Thermal quenching mechanisms of the Eu3+ luminescence in Ca9Al(PO4)7 obtained by citric route", Materials Research Bulletin, Vol. 48, I.2, 337 (2013). CrossRef I. Fryc, S. W. Brown, Y. Ohno, "A spectrally tunable LED sphere source enables accurate calibration of tristimulus colorimeters", Proc. SPIE Vol. 6158, 125 (2006) CrossRef Y. Ohno, "Practical Use and Calculation of CCT and Duv", LEUKOS, 10:1, 47-55, (2014). CrossRef D. Durmus, "Multi-objective optimization trade-offs for color rendition, energy efficiency, and circadian metrics", Proc. SPIE Vol. 11706, 117061J (2021) CrossRef I. Fryc, D. Czyzewski, " Dokładność pomiarowa spektroradiometrów typu CCD", Przeglad Elektrotechniczny R. 85(11), 276 (2009). DirectLink D. Czyzewski, "Zamienniki LED klasycznych żarówek", Przeglad Elektrotechniczny R. 88(11), 123 (2012). DirectLink J. Kusznier, W. Wojtkowski, "Spectral properties of smart LED lamps", Phot. Lett. Pol., 12(1), 16 (2020). CrossRef P. Hung, J. Y. Tsao, "Maximum White Luminous Efficacy of Radiation Versus Color Rendering Index and Color Temperature: Exact Results and a Useful Analytic Expression", Journ. of Display Techn., 9(6), 405 (2013). CrossRef Y. Asano, MD Fairchild, L. Blondé, "Individual Colorimetric Observer Model", PLOS ONE 11(2) e0145671 (2016). CrossRef Y. Wang, M. Wei, "Preference among light sources with different Duv but similar colour rendition: A pilot study", Lighting Res. & Tech., 50(7), 1013 (2018). CrossRef K. A. G. Smet, "Tutorial: The LuxPy Python Toolbox for Lighting and Color Science", LEUKOS, 16:3, 179 (2020). CrossRef D. Petrisor, C. D. Galatanu, C. Haba, L. Breniuc "Color Quality Measurements of LED Light Sources Using Image Processing", EEEIC/I&CPS Europe, 1, (2019) CrossRef ANSI C78.377:2017 DirectLink I. Fryc, T. Dimitrova-Grekow, "An Automated System for Evaluation of the Quality of Light Sources", 2016 IEEE (Lumen V4), 1 (2016). CrossRef Y. Ohno, "Spectral design considerations for white LED color rendering", Optical Engineering 44(11), 111302 (2005). CrossRef E. Purwanto, P. Dupuis, L. Canale, N. I. Sinisuka, G. Zissis, "Aging study of remote luminophore at ambient temperature", EEEIC/I&CPS Europe, 1 (2019). CrossRef J. Fan, Y. Li, I. Fryc, C. Qian, X. Fan, G. Zhang, "Machine-Learning Assisted Prediction of Spectral Power Distribution for Full-Spectrum White Light-Emitting Diode", IEEE Photonics Journal, 12(1), 1 (2020). CrossRef D. Mozyrska, M. Wyrwas, I. Fryc, "Wyznaczanie parametrów kolorymetrycznych LEDa w pełnym zakresie temperatur pracy", Przeglad Elektrotechniczny R. 93(4a), 232 (2012). CrossRef I. Fryc, "Analiza właściwości spektralnych LEDów z zależności od temperatury i natężenia ich prądu pracy", Przeglad Elektrotechniczny R. 86(10), 187 (2010). DirectLink I. Fryc, "Pomiary wybranych parametrów świetlno-optycznych LEDów według zaleceń Międzynarodowej Komisji Oświetleniowej CIE 127:2007", Przeglad Elektrotechniczny R. 85(11), 317 (2009). DirectLink A. David et al., "Development of the IES method for evaluating the color rendition of light sources", Opt. Express 23, 15888 (2015). CrossRef S Jost-Boissard, P Avouac, M Fontoynont, "Assessing the colour quality of LED sources: Naturalness, attractiveness, colourfulness and colour difference", Lighting Research & Technology, 47(7): 769 (2015). CrossRef J. Kowalska, "Określanie jakości oddawania barw źródeł światła parametrami przedstawionymi w zaleceniach IES TM-30-15 i CIE 013.3-1995", Przeglad Elektrotechniczny R. 93(6), 50 (2017). DirectLink J. Kowalska, I. Fryc, "Jakość oddawania barw współczesnych lamp fluorescencyjnych określona zdefiniowanym przez CIE wskaźnikiem wierności barwy oraz wskaźnikiem oddawania barw", Przeglad Elektrotechniczny R. 95(7), 94 (2019). DirectLink CIE 170-2:2015 DirectLink

Publisher

Photonics Society of Poland

Subject

Electronic, Optical and Magnetic Materials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3