Inter-rater reliability of the radiographic assessment of simple bone cysts

Author:

Cho S.1,Yankanah R.1,Babyn P.2,Stimec J.3,Doria A. S.3,Stephens D.4,Wright J. G.1

Affiliation:

1. Department of Surgery, The Hospital for Sick Children, Toronto, Ontario, Canada

2. Department of Medical Imaging, University of Saskatchewan and Saskatoon Health Region, Saskatoon, Saskatchewan, Canada

3. Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, Ontario, Canada

4. Research Institute, The Hospital for Sick Children, Toronto, Ontario, Canada

Abstract

Purpose To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods Methods Radiographic criteria were developed based on the literature and expert consensus. A single anteroposterior/lateral radiograph from 32 subjects with SBC were evaluated by three radiologists. A second reading was then conducted using revised criteria including a visual schematic. In the third reading the same images were assessed but radiologists had access to images from two additional time points. Inter-rater reliability was assessed after each reading using kappa (κ) and percentage agreement for categorical and binary parameters and intra-class correlation coefficient (ICC) for continuous parameters. Results Parameters that were revised with more explicit definitions including the visual schematic demonstrated consistent or improved inter-rater reliability with the exception of continuous cortical rim present and cyst location in the metaphysis and mid-diaphysis. Cortical rim displayed only slight reliability throughout (κ= -0.008 to 0.16). All other categorical parameters had a percentage agreement above 0.8 or a moderate (κ= 0.41 to 0.60), substantial (κ = 0.61 to 0.80) or almost perfect inter-rater reliability (κ = 0.81 to 1.0) in at least one reading. All continuous parameters demonstrated excellent inter-rater reliability (ICC > 0.75) in at least one reading with the exception of scalloping (ICC = 0.37 to 0.70). Inter-rater reliability values did not indicate an obviously superior method of assessment between single and serial chronological readings. Conclusion Explicit criteria for SBC parameters used in their assessment demonstrated improved and substantial inter-rater reliability. Inter-rater reliability did not differ between single and serial chronological readings. Level of Evidence Not Applicable

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Pediatrics, Perinatology and Child Health

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3