Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA

Author:

Guyen Olivier1

Affiliation:

1. Department of Orthopaedic Surgery, Lausanne University Hospital, Lausanne, Switzerland

Abstract

Dislocation remains a common cause of failure after total hip arthroplasty. The limitations of existing approaches to address instability have led to the development of powerfull options: constrained liners, dual mobility and large heads. These implant-related options have proven to be very efficient, but have raised concerns. With constrained liners, restricted range of motion (ROM) is responsible for impingement leading to high likelihood of failure, depending on the design, with various failure modes. Improvements of the bearing materials have addressed some of the concerns about increased volumetric wear of conventional polyethylene and offer an option to reduce instability: large diameter heads have the advantage of increased ROM before impingement, increased head-neck ratio, and jump distance. Highly cross-linked polyethylene helps address the risk for increased wear, and also large heads provide improved stability without the risk of mechanical failures observed with constrained liners. However, the increase of the head size remains limited as reducing the thickness of the liner may lead to fractures. In addition, the jump distance decreases as the cup abduction increases. The dual mobility concept simultaneously attempts to address head-neck ratio, constraint, and jump distance. Despite the need for longer follow-up, concerns raised about potential increased wear and intra-prosthetic dislocation with first generation implants have been addressed with modern designs. With a dramatic increase of the head-neck ratio whilst reducing the risk of mechanical failure or excessive wear, dual mobility THA outperforms large diameter heads and constrained liners at 10 years follow-up. For these reasons, dual mobility continues to gain interest worldwide and is becoming the most popular option to manage instability. Cite this article: Guyen O. Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 2016;1:197-204. DOI: 10.1302/2058-5241.1.000054.

Publisher

Bioscientifica

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3