EFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty

Author:

Tucker Keith1,Günther Klaus-Peter2,Kjaersgaard-Andersen Per3,Lützner Jörg2,Kretzer Jan Philippe4,Nelissen Rob G.H.H.5ORCID,Lange Toni6,Zagra Luigi7

Affiliation:

1. Orthopaedic Data Evaluation Panel (ODEP), Norwich, UK

2. University Centre of Orthopedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus Dresden, Technische Universität Dresden, Germany

3. Department of Orthopaedics, Vejle Hospital, South Danish University, Vejle, Denmark

4. Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany

5. Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands

6. Center for Evidence-based Healthcare, University Hospital Carl Gustav Carus and Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Germany

7. IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy

Abstract

Off-label use is frequently practiced in primary and revision arthroplasty, as there may be indications for the application of implants for purposes outside the one the manufacturers intended. Under certain circumstances, patients may benefit from selective application of mix & match. This can refer to primary hip arthroplasty (if evidence suggests that the combination of devices from different manufacturers has superior results) and revision hip or knee arthroplasty (when the exchange of one component only is necessary and the invasiveness of surgery can be reduced). Within the EFORT ‘Implant and Patient Safety Initiative’, evidence- and consensus-based recommendations have been developed for the safe application of off-label use and mix & match in primary as well as revision hip and knee arthroplasty. Prior to the application of a medical device for hip or knee arthroplasty off-label and within a mix & match situation, surgeons should balance the risks and benefits to the patient, obtain informed consent, and document the decision process appropriately. Nevertheless, it is crucial for surgeons to only combine implants that are compatible. Mismatch of components, where their sizes or connections do not fit, may have catastrophic effects and is a surgical mistake. Surgeons must be fully aware of the features of the components that they use in off-label indications or during mix & match applications, must be appropriately trained and must audit their results. Considering the frequent practice of off-label and mix & match as well as the potential medico-legal issues, further research is necessary to obtain more data about the appropriate indications and outcomes for those procedures. Cite this article: EFORT Open Rev 2021;6:982-1005. DOI: 10.1302/2058-5241.6.210080

Publisher

Bioscientifica

Subject

Orthopedics and Sports Medicine,Surgery

Reference116 articles.

1. Medicines and Healthcare products Regulatory Agency (MHRA). Guidance: off-label use of a medical device 2014. https://www.gov.uk/government/publications/medical-devices-off-label-use/off-label-use-of-a-medical-device. (date last accessed 30 April 2021).

2. Prevalence and Perioperative Outcomes of Off-Label Total Hip and Knee Arthroplasty in the United States, 2000–2010

3. Nationwide review of mixed and non-mixed components from different manufacturers in total hip arthroplasty

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3