Author:
O'Bierne J,Boyer MI,Axelrod TS
Abstract
We performed 45 wrist arthrodeses in 43 patients by a modification of the AO technique using the dynamic compression plate. Radiological follow-up was obtained in 41 wrists; all had united at a mean of ten weeks. Clinical follow-up was obtained in 32 wrists. Subjectively, the surgical outcome was satisfactory in 26, marginally satisfactory in two and unsatisfactory in four. This method is safe and reliable. The plate can be contoured to allow a variety of positions of fusion, and gives rigid immobilisation. The rate of union is higher than that for other techniques.
Publisher
British Editorial Society of Bone & Joint Surgery
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
48 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献