Affiliation:
1. Department of Orthopaedics, Leiden Universitair Medisch Centrum, Leiden, Netherlands
2. Department of Orthopaedics, Spaarne Gasthuis Hoofddorp, Hoofddorp, Netherlands
3. SCORE, Specialized Centre of Orthopedic Research and Education, Xpert Orthopedie Amsterdam, Amsterdam, Netherlands
Abstract
Aims The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs. Methods A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses. Results The mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group. Conclusion The mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected. Cite this article: Bone Joint J 2023;105-B(2):148–157.
Publisher
British Editorial Society of Bone & Joint Surgery
Subject
Orthopedics and Sports Medicine,Surgery
Reference39 articles.
1. Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?
2. No authors listed. Online LROI annual report 2021. Dutch Arthroplasty Register (LROI). 2021. https://www.lroi-report.nl/app/uploads/2022/02/PDF-LROI-annual-report-2021.pdf (date last accessed 15 December 2022).
3. No authors listed. 18th Annual Report 2021. National Joint Registry. 2021. https://reports.njrcentre.org.uk/Portals/12/PDFdownloads/NJR%2018th%20Annual%20Report%202021.pdf (date last accessed 15 December 2022).
4. How Large a Study Is Needed to Detect TKA Revision Rate Reductions Attributable to Robotic or Navigated Technologies? A Simulation-based Power Analysis
5. RSA and Registries: The Quest for Phased Introduction of New Implants
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献