Abstract
Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.