A prospective radiostereometric analysis of the stability of a metal-backed glenoid component/autograft composite in reverse shoulder arthroplasty

Author:

Cunningham Lindsay J.1ORCID,Walton Mike1,Bale Steve1,Trail Ian A.1ORCID

Affiliation:

1. Upper Limb Research Department, Wrightington Hospital, Wrightington, UK

Abstract

AimsReverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).MethodsA total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.ResultsRSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001).ConclusionThese findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation.Cite this article: Bone Joint J 2023;105-B(8):912–919.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference38 articles.

1. Trabecular TitaniumTM cups and augments in revision total hip arthroplasty: clinical results, radiology and survival outcomes;Gallart;Hip Int,2016

2. Angled BIO-RSA (bony-increased offset-reverse shoulder arthroplasty): a solution for the management of glenoid bone loss and erosion;Boileau;J Shoulder Elbow Surg,2017

3. Does metal porosity affect metal ion release in blood and urine following total hip arthroplasty? A short term study;Bistolfi;Hip Int,2018

4. (Glenoid reconstruction in revision shoulder arthroplasty);Gohlke;Oper Orthop Traumatol,2019

5. No authors listed . National Joint Registry 17th Annual Report 2020 . National Joint Registry . 2021 . https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2017th%20Annual%20Report%202020.pdf ( date last accessed 12 June 2023 ).