Author:
Kousa P,Jarvinen TL,Pohjonen T,Kannus P,Kotikoski M,Jarvinen M
Abstract
We compared the strength of fixation of a biodegradable screw with that of two metal screws in a bone-patellar-tendon-bone (BPTB) graft in the bovine knee. We used 33 fresh BPTB specimens with a circular tibial bone plug of 9 mm in diameter which were anchored in a tibial metaphyseal bone tunnel with either an interference screw (n = 11), an AO cancellous screw (n = 11) or a fibrillated, self-reinforced biodegradable poly-L-lactide screw (n = 11). The mean force to failure (+/- SD) in the three groups was 1358 +/- 348 N, 1081 +/- 331 N and 1211 +/- 362 N, respectively. There was no significant difference in the groups with regard to the linear load or the elastic moduli of the fixation. We conclude that the biodegradable screw is as good as either of the two metal screws in the fixation of a BPTB graft in the bovine knee and can be recommended for ACL reconstruction using this type of graft.
Publisher
British Editorial Society of Bone & Joint Surgery
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
58 articles.
订阅此论文施引文献