Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis

Author:

Galea V. P.1,Rojanasopondist P.1,Laursen M.2,Muratoglu O. K.13,Malchau H.13,Bragdon C.13

Affiliation:

1. Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts, USA.

2. Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark.

3. Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts, USA.

Abstract

Aims Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (sd 0.16) and 0.00 mm (sd 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (sd 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (sd 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference40 articles.

1. No authors listed. Australian Orthopaedic Association National Joint Replacement Registry: Hip, knee & shoulder arthroplasty: 2017 annual report, 2017. https://aoanjrr.sahmri.com/documents/10180/397736/Hip%2C%20Knee%20%26%20Shoulder%20Arthroplasty (date last accessed 29 April 2019).

2. No authors listed. American Joint Replacement Registry: 2017 annual report. http://connect.ajrr.net/2017-annual-report-download?hsCtaTracking=211910d3-f75a-440c-8bff-9d3da22c75ad%7C2cb33f5d-6e5a-405d-b3c6-dc5e1914c660 (date last accessed 22 May 2019).

3. Kärrholm J, Lindahl H, Malchau H, et al. The Swedish Hip Arthroplasty Register: annual report 2016, 201620162016. https://registercentrum.blob.core.windows.net/shpr/r/Annual-Report-2016-B1eWEH-mHM.pdf (date last accessed 29 April 2019).

4. Free radicals trapped in polyethylene crystals

5. A study of long-lived free radicals in gamma-irradiated medical grade polyethylene

同舟云学术