Affiliation:
1. Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
2. Safety & Security Science and Centre for Safety in Healthcare, Delft University of Technology, Delft, Netherlands
3. Department of Orthopaedics, Hässleholm Hospital, Hässleholm, Sweden
4. Department of Clinical Sciences, Lund University, Lund, Sweden
Abstract
AimsThe objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.MethodsOverall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up.ResultsMean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033).ConclusionThe Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening.Cite this article: Bone Joint J 2024;106-B(2):136–143.
Publisher
British Editorial Society of Bone & Joint Surgery
Reference35 articles.
1. No authors listed
.
Online LROI Annual report 2022
.
Dutch Arthroplasty Register (LROI)
.
2022
.
https://www.lroi-report.nl/previous-reports/online-lroi-report-2022/
(
date last
accessed
20 July 2023
).
2. No authors listed
.
The New Zealand Joint Registry (NZJR) 23 Year Report
.
New Zealand Orthopaedic Association (NZOA)
.
2023
.
https://www.nzoa.org.nz/annual-reports
(
date last
accessed
20 July 2023
).
3. No authors listed
.
National Joint Registry (NJR) 2022
.
National Joint Registry (NJR)
.
2022
.
https://www.njrcentre.org.uk/njr-annual-report-2022/
(
date last
accessed
4 December 2023
).
4. No authors listed
.
Annual report 2022
.
Australian Orthopaedic Assocation National Joint Replacement Registry (AOANJRR)
.
2022
.
https://aoanjrr.sahmri.com/annual-reports-2022
(
date last
accessed
1 July 2023
).
5. No authors listed
.
Trident Acetabular Shell Systems
.
Stryker
.
2023
.
https://www.stryker.com/us/en/joint-replacement/products/trident.html
(
date last
accessed
22 September 2023
).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献