Surface finish of the Exeter Trauma Stem

Author:

Petheram T. G.1,Bone M.2,Joyce T. J.2,Serrano-Pedraza I.3,Reed M. R.1,Partington P. F.1

Affiliation:

1. Wansbeck General Hospital, Woodhorn Lane, Ashington, Northumberland NE63 9JJ, UK.

2. Newcastle University, Claremont Road, Newcastle upon Tyne NE1 1RU, UK.

3. Complutense University of Madrid, Campus De Somosaguas, Madrid 28223, Spain.

Abstract

Recent guidance recommends the use of a well-proven cemented femoral stem for hemiarthroplasty in the management of fractures of the femoral neck, and the Exeter Trauma Stem (ETS) has been suggested as an example of such an implant. The design of this stem was based on the well-proven Exeter Total Hip Replacement stem (ETHRS). This study assessed the surface finish of the ETS in comparison with the ETHRS. Two ETSs and two ETHRSs were examined using a profilometer with a precision of 1 nm and compared with an explanted Exeter Matt stem. The mean roughness average (RA) of the ETSs was approximately ten times higher than that of the ETHRSs (0.235 μm (0.095 to 0.452) versus 0.025 μm (0.011 to 0.059); p < 0.001). The historical Exeter Matt stem roughness measured a mean RA of 0.973 μm (0.658 to 1.159). The change of the polished Exeter stem to a matt surface finish in 1976 resulted in a high stem failure rate. We do not yet know whether the surface differences between ETS and ETHRS will be clinically significant. We propose the inclusion of hemiarthroplasty stems in national joint registries. Cite this article: Bone Joint J 2013;95-B:173–6.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference31 articles.

1. No authors listed. NICE clinical guideline: the management of hip fracture in adults. http://www.nice.org.uk/nicemedia/live/13489/54919/54919.pdf (date last accessed 11 October 2012).

2. No authors listed. Exeter hip website: new developments: ETS. http://www.exeterhip.co.uk/ex_pag_ets.htm (date last accessed 11 October 2012).

3. Migration, Stem Shape, and Surface Finish in Cemented Total Hip Arthroplasty

4. FEMORAL STEM FIXATION

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3