Affiliation:
1. Nuffield Department of Orthopaedics, Rheumatology
and Musculoskeletal Sciences, Botnar Research
Centre, Windmill Road, Oxford
OX3 7LD, UK.
2. Nuffield Orthopaedic Centre, Windmill
Road, Oxford OX3 7LD, UK.
Abstract
Recent events have highlighted the importance of implant design for survival and wear-related complications following metal-on-metal hip resurfacing arthroplasty. The mid-term survival of the most widely used implant, the Birmingham Hip Resurfacing (BHR), has been described by its designers. The aim of this study was to report the ten-year survival and patient-reported functional outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of 51.9 years (16.5 to 81.5) followed for a mean of eight years (1 to 12), the survival and patient-reported functional outcome depended on gender and the size of the implant. In female hips (n = 267) the ten-year survival was 74% (95% confidence interval (CI) 83 to 91), the ten-year revision rate for pseudotumour was 7%, the mean Oxford hip score (OHS) was 43 (sd 8) and the mean UCLA activity score was 6.4 (sd 2). In male hips (n = 379) the ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate for pseudotumour was 1.7%, the mean OHS was 45 (sd 6) and the mean UCLA score was 7.6 (sd 2). In the most demanding subgroup, comprising male patients aged < 50 years treated for primary osteoarthritis, the survival was 99% (95% CI 97 to 100). This study supports the ongoing use of resurfacing in young active men, who are a subgroup of patients who tend to have problems with conventional THR. In contrast, the results in women have been poor and we do not recommend metal-on-metal resurfacing in women. Continuous follow-up is recommended because of the increasing incidence of pseudotumour with the passage of time.
Publisher
British Editorial Society of Bone & Joint Surgery
Subject
Orthopedics and Sports Medicine,Surgery
Reference31 articles.
1. No authors listed. Medicines and Healthcare products Regulatory Agency (MHRA). Medical Device Alert: All metal-on-metal (MoM) hip replacements, 2012 (MDA/2012/008 2012). http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON079157 (date last accessed 27 April 2012).
2. Meier B. The New York Times: Hip implant complaints surge, even as the dangers are studied, 2011. http://www.nytimes.com/2011/08/23/business/complaints-soar-on-hip-implants-as-dangers-are-studied.html (date last accessed 27 April 2012).
3. Blood metal ion concentrations after hip resurfacing arthroplasty
4. Ten-year results of a double-heat-treated metal-on-metal hip resurfacing
5. No authors listed. The Birmingham Hip Resurfacing System. http://www.hipresurfacing.com/ (date last accessed 27 April 2012).
Cited by
102 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献