A comparative assessment of small-head metal-on-metal and ceramic-on-polyethylene total hip replacement

Author:

Lübbeke A.1,Gonzalez A.1,Garavaglia G.1,Roussos C.1,Bonvin A.1,Stern R.1,Peter R.1,Hoffmeyer P.1

Affiliation:

1. Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland.

Abstract

Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen. In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern. Cite this article: Bone Joint J 2014; 96-B:868–75.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference44 articles.

1. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements

2. No authors listed. Australian Orthopaedic Association National Joint Replacement Registry. Annual report 2010. https://aoanjrr.dmac.adelaide.edu.au/annual-reports-2010 (date last accessed 16 May 2014).

3. No authors listed. National Joint Registry for England and Wales. 7th Annual Report 2010, http://www.njrcentre.org.uk/njrcentre/AbouttheNJR/Publicationsandreports/Annualreports/Archivedannualreports/tabid/87/Default.aspx (date last accessed 16 May 2014).

4. No authors listed. New Zealand Orthopaedic Association. The New Zealand Joint Registry: eleven year report: January 1999 to December 2009, http://www.nzoa.org.nz/nz-joint-registry (date last accessed 16 May 2014).

5. A Multinational Assessment of Metal-on-Metal Bearings in Hip Replacement

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3