MIGRATION OF CEMENTED FEMORAL COMPONENTS AFTER THR

Author:

Kiss J.1,Murray D. W.2,Turner-Smith A. R.3,Bithell J. F.4,Bulstrode C. J.2

Affiliation:

1. Department of Orthopaedics, Semmelweis University of Medicine, Budapest, Karolina ut 27, 1113 Hungary.

2. Nuffield Department of Orthopaedic Surgery, University of Oxford, Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford OX3 7LD, UK.

3. King’s College School of Medicine and Dentistry, Denmark Hill, London SE5 9RS, UK.

4. University of Oxford, 1 South Parks Road, Oxford OX1 3TG, UK.

Abstract

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed. The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane. The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司