Affiliation:
1. Department of Orthopaedic Surgery, Queen's University of Belfast, Musgrave Park Hospital, Northern Ireland.
Abstract
The effect of Charnley cemented total hip replacement on venous blood flow in the legs and its relationship to deep-vein thrombosis were investigated in 413 patients. Blood flow was measured using strain-gauge plethysmography before operation, after surgery, and after discharge from hospital. There was a significant reduction in both venous capacitance and venous outflow, affecting both legs but greater in the operated leg. Venous flow remained significantly below preoperative levels in the operated leg six weeks after surgery. There was a highly significant correlation between the degree of reduction in blood flow and the development of postoperative deep-vein thrombosis. Venous stasis was shown to be a major factor in venous thrombogenesis.
Publisher
British Editorial Society of Bone & Joint Surgery
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
60 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献