Cementless metal-backed patellar components in primary total knee arthroplasty using an implant of modern design

Author:

Baker James F.1,Nadar Arun C.2,Jouflas Alex C.3,Smith Langan S.1,Sachdeva Shikha3,Yakkanti Madhusudhan R.4,Malkani Arthur L.5ORCID

Affiliation:

1. UofL Health, ULP Orthopedics, Louisville, Kentucky, USA

2. University of Louisville School of Medicine, Louisville, Kentucky, USA

3. Department of Orthopedic Surgery, University of Louisville, Louisville, Kentucky, USA

4. Louisville Orthopaedic Clinic, Louisville, Kentucky, USA

5. Adult Reconstruction Program, Dept. of Orthopedic Surgery, University of Louisville, Louisville, Kentucky, USA

Abstract

AimsThe use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.MethodsThis was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.ResultsA total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years.ConclusionThe second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years.Cite this article: Bone Joint J 2023;105-B(12):1279–1285.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献