The Effect of the Use of Activation 3D Mapping on the Patient X-Ray Load During Radiofrequency Ablation of Typical Atrial Flutter

Author:

Yakushev Andriy V.ORCID,Kravchuk Borys B.ORCID

Abstract

Supraventricular macro re-entry tachyarrhythmias occupy the leading places among all types of tachyarrhythmias. The most common in this category is typical atrial flutter (AFL). This heart rhythm disorder has a negative impact on the patients’ quality of life. Its complications can lead to disability and death due to possible thromboembolism. Therapeutic treatment is limited in effectiveness. The main method of intervention is catheter radiofrequency ablation (RFA). The standard approach of RFA of AFL is performed without the use of navigation systems under fluoroscopy guidance. However, this results in an increased radiation exposure to the patient and the medical personnel. Modern technologies in the field of invasive electrophysiology make it possible to create anatomical models of heart and reproduce the spread of electrical excitation. However, the routine use of additional navigation methods remains controversial. The aim. To compare the duration of RFA of typical AFL and radiation exposure with the use of anatomical and propagation mapping. Materials and methods. This study is based on the analysis of the treatment results obtained for 53 patients at the National Amosov Institute of Cardiovascular Surgery in the period from 2014 to 2023. Depending on imaging methods, the patients were divided into two groups. The first group included 27 patients with an anatomical mapping of the right atrium. The second group included 26 patients with propagation mapping. Results. In all the patients we have achieved a bidirectional conduction block through cavotricuspid isthmus. In the first group, the total duration of confirming the diagnosis and creating the anatomical model was 312 ± 26 seconds. The mean time to the moment of AFL termination and restoration of sinus rhythm was 230 ± 19 seconds. The average duration of the procedure was 41.5 ± 3.5 minutes, the average fluoroscopy time was 120 ± 10 seconds, the average dose area product (DAP) was 15 ± 1.3 Gy·cm2. In the second group, the average time for creating a 3D propagation model of right atrium and verifying the diagnosis was 748 ± 65 seconds. The average time from the first application to the termination of tachycardia was 227 ± 20 seconds. The average duration of the procedure was 55 ± 4.7 minutes, X-ray time was 93 ± 8 seconds, average DAP was 13 ± 1.1 Gy·cm2. The duration of the procedure in the second group was significantly longer (p = 0.03), however, the radiation exposure and DAP were not statistically different (p = 0.31) between the observation groups. Conclusions. The use of propagation mapping increases the time of the procedure by 24.5% and does not give a significant advantage in reducing the radiation exposure. The use of a navigation system during cavotricuspid isthmus RFA is recommended for concomitant radical treatment of complex supraventricular arrhythmias, such as atrial fibrillation.

Publisher

Professional Edition Eastern Europe

Reference13 articles.

1. Katritsis DG, Boriani G, Cosio FG, Hindricks G, Jaïs P, Josephson ME, et al. European Heart Rhythm Association (EHRA) consensus document on the management of supraventricular arrhythmias, endorsed by Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulación Cardiaca y Electrofisiologia (SOLAECE). Europace. 2017;19(3):465-511. https://doi.org/10.1093/europace/euw301

2. Vadmann H, Nielsen PB, Hjortshoj SP, Riahi S, Rasmussen LH, Lip GY, et al. Atrial flutter and thromboembolic risk: a systematic review. Heart. 2015;101(18):1446-1455. https://doi.org/10.1136/heartjnl-2015-307550

3. Benjamin EJ, Muntner P, Alonso A, Bittencourt MS, Callaway CW, Carson AP, et al.; American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee. Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association. Circulation. 2019;139(10):e56-e528. https://doi.org/10.1161/CIR.0000000000000659

4. Wagner S, Chaudhry SP, Ali S, Arman HE, Padanilam BJ, Gilge JL, et al. Atrial Fibrillation/Atrial Flutter Tachy-Cardiomyopathy: New Observations on Cardiac MRI and Treatment. JACC Clin Electrophysiol. 2023;9(3):416-418. https://doi.org/10.1016/j.jacep.2022.09.024

5. Saoudi N, Cosio F, Waldo A, Chen SA, Iesaka Y, Lesh M, et al. Classification of Atrial Flutter and Regular Atrial Tachycardia According to Electrophysiologic Mechanism and Anatomic Bases: A Statement from a Joint Expert Group from the Working Group of Arrhythmias of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. J Cardiovasc Electrophysiol. 2001;12(7):852-866. https://doi.org/10.1046/j.1540-8167.2001.00852.x

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3