Endovascular Closure of Secondary Septal Defect in Children with Low Body Weight

Author:

Ditkivskyy Igor O.ORCID,Voloshyn Denys L.ORCID,Yermolovych Yuliia V.ORCID,Perepeka Iryna A.ORCID,Lazoryshynets Vasyl V.ORCID

Abstract

The aim. To assess the effectiveness and safety of transcatheter closure of a secondary atrial septal defect (ASD) using an occluder in symptomatic children weighing ≤10 kg. Materials and methods. In the period from November 2014 to June 2021, on the basis of the National Amosov Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine, closure of secondary ASD using an occluder was performed in 18 patients, among them 13 women (72.2%) and 5 men (27.8%). Th e mean age of the patients was 18.94±9.44 months (the youngest patient was 12 months, the oldest was 4 years). The mean weight was 9.294±1.170 kg (6.4 kg to 10 kg), the mean Z-score was -1.7±1.5 (-4.6 to 0.46), the mean height was 80 cm (71 cm to 88 cm). According to the measurements by transesophageal echocardiography (TEE), the average size of the defects was 13.7 mm±3.6mm (the largest 18.0 mm, the smallest 6.0 mm). Results and discussion. In our publication, the effectiveness of the method was 100% (18/18), while the world statistics show 94-95%. Th e frequency of complications was 5.6% (n=1). We suggest that this is associated with the use of a sizing balloon and careful selection of the device. When choosing treatment tactics for symptomatic children weighing ≤10 kg, the decisive factor was the determination of the presence of edges and the size of the defect. Defects were considered suitable for closure, according to TEE data, when all margins of the defect were ≥4 mm, except for the aortic margin. Although the total length of the interatrial membrane was taken into account, it was not of decisive importance, since for most occluders with the presence of all edges, the fields of the implant could not interfere with the work of the anatomical structures of the heart. To determine the real size of the defect, we recommend a measuring balloon under TEE control. The following devices were used to close the defect: MemoPart ASD occluder, Amplatzer Septal Occluder, LifeTech HeartR Occluder, LifeTech HeartR Multi-Fenestrated Atrial Septal Defect (MF-ASD) Occluder.   Conclusion. After the study, we are convinced that the endovascular method of closing a hemodynamically significant secondary ASD for the treatment of children with a body weight of ≤10 kg has proven to be an effective method, with successful implantation of the occluder in 100% of cases.

Publisher

Professional Edition Eastern Europe

Subject

Cardiology and Cardiovascular Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Endovascular Closure of Secundum Atrial Septal Defects with Complex Anatomy;Ukrainian Journal of Cardiovascular Surgery;2023-03-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3