Industrial plants are huge consumers of energy, these plants are installing heat exchangers in an effort to reduce energy consumption, and so improve operating efficiencies. Limited numbers of experimental and numerical investigations have dealt with the parameters affecting the heat transfer aspects in single phase direct contact heat exchangers which may be selected for their high thermal efficiency and minimum capital investment. In oil refineries energy from hot temperature oil streams can be recovered by transfer directly to a cheap coolant liquid in liquid-liquid direct contact heat exchangers. The heat recovered from these heat exchangers has different applications including preheating boiler feed water and preheating wash water. Heat recovery from hot temperature refinery products using direct contact heat exchanger throughout a theoretical phenomenological study is central to the theme of this paper. Kerosene-water system has been chosen. The effect of the heating fluid inlet temperature (65-97.50)°C, and mass flow rate (25 to 45) kg/s on direct contact heat exchanger design parameters and heat transfer characteristics were investigated theoretically throughout nine cases. Correlations of heat recovered from the system as well as design and operating characteristics of the heat exchanger were estimated. Increasing kerosene flow rate found to associate directly with increasing the contact surface area, number of plates, number of channels per pass and pressure drop, while when the heat exchanger is designed to operates at high kerosene inlet temperature, big heat exchangers with large areas, high number of plates and channels per pass are needed for efficient heat exchanger performance. Optimization and modeling the effect of kerosene operating variables on heat recovered was conducted using Response Surface Methodology. The results showed that an optimum heat recovery value of 6.8782 megawatt could be achieved for kerosene optimum inlet temperature (91.82°C), and mass flow rate (50.11 kg/s). Keywords: direct contact heat exchanger; kerosene and water system, kerosene mass flow rate and inlet temperature.

Publisher

Education Support and Investment Fund NGO

Subject

Immunology

Reference5 articles.

1. H.B. Mahood, A.N. Campbell, R.B. Thorpe, A.O. Sharif, Heat transfer efficienceven and capital cost evaluation of a three-phase direct contact heat exchanger for the utilisation of low-grade energy sources, Energy Convers. Manage. 106 (2015) 101–109. 2. H.B. Mahood, R.B. Thorpe, A.N. Campbell, A.O. Sharif, Experimental measurements and theoretical prediction for the transient characteristic of a three-phase direct contact condenser, J. Appl. Therm. Eng. 87 (2015) 161–174. 3. G.L. Bauerle, R.C. Ahlert, Heat transfer and holdup phenomena in spray column, Ind. Eng. Chem. Process Des. Dev. 4 (2) (1965) 225–230.

2. S.B. Plass, H.R. Jacobs, R.F. Boehm, Operational characteristics of a spray column type direct contact contactor preheater, AIChE Symp. Ser.-Heat Transfer 75 (189) (1979) 227–234. 5. P. Goodwin, M. Coban, R. Boehm, Evaluation of the flooding limits and heat transfer of a direct contact three phase spray column, in: National Heat Transfer Conference, Denver, August, 1985, pp. 1–5. 6. J. Siqueiros, O. Bonilla, An experimental study of a three-phase, direct-contact heat exchanger, Appl. Therm. Eng. 19 (5) (1999) 477–493.

3. M. Song, A. Steiff, P.-M. Weinspach, The analytical solution for a model of direct contact evaporation in spray columns, Int. Commun. Heat Mass Transfer 23 (2) (1996) 263–272. 8. Z. Peng, W. Yiping, G. Cuili, W. Kun, Heat transfer in gas–liquid–liquid threephase direct-contact exchanger, Chem. Eng. J. 84 (3) (2001) 381–388. 9. Y. Wang, H. Fu, Q. Huang, Y. Cui, Y. Sun, L. Jiang, Experimental study of direct contact vaporization heat transfer on n-pentane–water flowing interface, Energy 93 (2015) 854–863. 10. S. Sideman, G. Hirsch, Y. Gat, Direct contact heat transfer with change phase: effect of the initial drop size in three phase heat exchanger, AIChE J. 11 (6) (1965) 1081–1087.

4. P. Battya, V.R. Raghavan, K.N. Seetharamu, Parametric analysis of direct contact sensible heat transfer in spray column, Lett. Heat Mass Transfer 9 (4) (1982) 265–276. 12. K.L. Core, J.C. Mulligan, Heat transfer and population characteristics of dispersed evaporating droplets, AIChE J. 36 (8) (1990) 1137–1144.

5. S.M. Summers, C.T. Crowe, One-dimensional numerical model for a spray column heat exchanger, AIChE J. 37 (11) (1991) 1673–1679.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3