SANITARY PROTECTION ZONES BY NOISE FACTOR FROM GAS DISTRIBUTION POINTS
Author:
Tupov Vladimir,Skvortsov Vitaliy
Abstract
The power equipment of thermal power plants is a source of noise to the surrounding area. One of the sources of noise for the surrounding area are gas distribution points (GDP) of thermal power plants (TPP) and district thermal power plants (RTS). Noise from gas distribution points may exceed sanitary standards at the border of the sanitary protection zone. The article shows that the radiated noise from gas distribution points depends on the power of the thermal power plant (natural gas consumption) and the type of valves. Three types of valves used in gas distribution points are considered. Formulas are obtained for calculating the width of the sanitary protection zone for gas distribution points for thermal stations, depending on the consumption of natural gas (electric power of the thermal power plant) and the type of valve. It is shown that, depending on the valve used, the noise level at the border of the sanitary protection zone can either meet sanitary standards or exceed them. This allows at the design stage to select the required type
of valve or to determine mitigation measures from hydraulic fracturing.
Publisher
Studio D - akustika s.r.o.
Subject
Acoustics and Ultrasonics