Affiliation:
1. Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt
Abstract
Abstract
This work studies the opto-thermo-mechanical properties of two different surgical sutures using interferometry. The polarizing Pluta interference microscope combined with opto-thermo-mechanical (OTM) device were used to study the effect of drawing on monofilament polyester (PET) and polyamide (PA) surgical sutures at room temperature. The variation of the refractive indices and the birefringence of both PET and PA sutures with different draw ratios were determined. The resulting data was used to calculate the optical orientation function and the average work per chain. The stress–strain curve was studied to estimate some mechanical parameters; yield stress, yield strain, Young's modulus and strain optical coefficient. The variations of the refractive the index profile were calculated for different draw ratios. In addition we studied the effect of temperature, during the drawing process, on monofilament PET suture. The obtained results provide important data for better characterization of suture materials.
Subject
Materials Chemistry,Industrial and Manufacturing Engineering,Polymers and Plastics,General Chemical Engineering
Reference22 articles.
1. On the Refractive Indexes and Birefringence of Nylon 6 Yarns as a Function of Draw Ratio and Strain;J. Polym. Sci.,(1975)
2. Selection of Wound Closure Materials;J. Amer. Acad. Dermato.,(1988)
3. Mechanical Properties of Suture Materials;Ann. Surg.,(1981)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献