Intergranular Corrosion in Unserviced Austenitic Stainless Steel Pipes Made of Alloy 904L
Author:
Neidel A.1,
Cagliyan E.1,
Fischer B.1,
Giller M.1,
Riesenbeck S.1
Affiliation:
1. Siemens AG , Energy Sector, Gasturbinenwerk Berlin, Werkstoffprüflabor, Huttenstraße 12 , D-10548 Berlin; e-mail:
Abstract
Abstract
Seamless tubes of the highly corrosion resistant austenitic steel 1.4539, X1NiCrMoCu25-20-5 (Alloy 904L) were observed to exhibit signs of inter-crystalline damage to a depth of several layers of grains and in particular on their internal surface. The material had been stored and had not been put into service. A number of hypotheses had been discussed to explain the predominant cause of the damage. Using optical light and scanning electron microscopy investigation techniques, clear evidence was obtained indicating it to be inter-crystalline corrosion due to the sensitisation of the grain boundaries. The most probable cause of this was determined to be the presence of residual deposits from the rolling process, which due to poor cleaning, had not been completely removed prior to the final solution annealing treatment. This explaining why predominantly the internal surface of the tubes was affected.
Publisher
Walter de Gruyter GmbH
Subject
Metals and Alloys,Mechanics of Materials,Condensed Matter Physics,Electronic, Optical and Magnetic Materials
Reference13 articles.
1. Ausgewählte Schadensfälle aus dem Großgasturbinenbau–Werden wir aus Schaden wirklich klug?;Materials Testing,2011
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献