External Calibration in PA12 Tube Extrusion

Author:

Carin A.1,Haudin J.-M.1,Vincent M.1,Monasse B.1,Bellet G.2,Amouroux N.2

Affiliation:

1. Centre de Mise en Forme des Matériaux, Ecole des Mines de Paris, Sophia Antipolis, France

2. Arkema, Cerdato, Serquigny, France

Abstract

Abstract In polyamide 12 (PA12) tube extrusion, calibration is crucial for the major final properties such as elongation at break or burst pressure. In external calibration, the extruded tube is pulled through a cylindrical calibrator located in a water tank under vacuum. A water flow rate is applied at the calibrator inner side, creating a lubricating water layer at the polymer outer surface. A combination of a quenching and a mechanical drawing was highlighted during calibration by on-line measurements. A subsequent high molecular orientation in the outer tube layers was also featured by X-Ray diffraction and birefringence evaluation in light microscopy. Besides, influence of lubrication level in the sizing-sleeve was investigated by an estimate of the lubricating water layer and a characterization of the tube final surface state in different calibration conditions. Firstly, we quantitatively showed that rising the water layer thickness leads to a diminution of the draw ratio in the calibration tank, DrCAL (ratio between line velocity and velocity at the calibrator entrance). Excellent correlation has been found between tube superficial orientation and DrCAL: a reduced elongation of the polymer in the calibrator leads to a lower level of superficial orientation. Secondly, two kinds of surface defects were detected on the tubes by light microscopy and microtopography. At last, several correlations were featured with mechanical properties. Elongation at break was found to strongly depend on the molecular orientation resulting from calibration. Moreover, origin of rupture was investigated during tensile testing in light microscopy. We emphasized that surface defects alignments perpendicular to the extrusion initiate the rupture by creating a significant crack via coalescence of initial defects. Thus, microstructure, surface state and tensile properties can be controlled by fitting the calibration parameters to improve lubrication and reduce the draw ratio in calibrator.

Publisher

Walter de Gruyter GmbH

Subject

Materials Chemistry,Industrial and Manufacturing Engineering,Polymers and Plastics,General Chemical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3